A Comparison of Technique Errors between Film and Photostimulable-phosphor (psp) Receptors

نویسندگان

  • Amy U. Nguyen
  • Sally M. Mauriello
  • Charlotte A. Peterson
  • Sally Mauriello
  • Charlotte Peterson
چکیده

This study evaluated the technique errors of full mouth series exposed with two intraoral radiography receptor systems; traditional film-based and PSP-based (photostimulable phosphor) receptors. Full mouth series (n=405) were randomly selected: three series per each student for film-based (n=81) and PSP-based (n=102). All images (1514 film and 1754 PSP images) were evaluated in four categories for technique errors: 1) horizontal, 2) vertical, 3) cone centering, 4) packet placement. Each image was graded based on the presence and degree of the error (no error, diagnostically acceptable error and diagnostically unacceptable). All images were evaluated using the same viewing conditions: viewbox for film images and a 17 " computer monitor for digital images at (1024 x 768 resolution) with no feature enhancements. More technique errors occurred with the use of the PSP receptors when compared to film (p<0.05). Further research should explore use of the PSP receptor with another film holding device. iii ACKNOWLEDGMENTS I would like to extend my thanks and appreciation to Dr. Sally Mauriello for her priceless advice, guidance, and extraordinary courage, Ms. Charlotte Peterson and Dr. Rick Platin for their generous feedback, advice and counsel. I am grateful to my family and friends for their unconditional love and support throughout this endeavor.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparison of Technique Errors using Two Radiographic Intra-oral Receptor-holding Devices.

PURPOSE Technological advances in intra-oral receptors have resulted in film-holding devices that may or may not be interchangeable with photostimulable phosphor receptors. This study evaluated the number and types of technique errors that occurred when using PSP receptors with a standard film-holding device and a dual PSP/film-designed device. METHODS The Rinn XCP-ORA® (Standard) and the Rin...

متن کامل

Comparison of technique errors of intraoral radiographs taken on film v photostimulable phosphor (PSP) plates.

OBJECTIVE The objective of this study was to compare the technical errors of intraoral radiographs exposed on film v photostimulable phosphor (PSP) plates. METHODS The intraoral radiographic images exposed on phantoms from preclinical practical exams of dental and dental hygiene students were used. Each exam consisted of 10 designated periapical and bitewing views. A total of 107 film sets an...

متن کامل

Comparison of Different Imaging Techniques for the Evaluation of Proximity between Molars and the Mandibular Canal

Background and Aim: To compare the radiographic distance from the inferior part of mandibular second and third molars to the superior border of mandibular canal on radiographs obtained by conventional periapical radiographs, intraoral photostimulable phosphor plate (Intraoral PSP) and panoramic photostimulable phosphor plate (Panoramic PSP). Subjects and Methods: The study was carried out on 25...

متن کامل

توموگرافی خطی با فیلم و Photostimulable Phosphor Plate در طرح درمان ایمپلنت در مندیبل

Background and Aims: Radiographic examination prior to implant placement is often complemented with tomography for location of vital anatomic structures and evaluation of bone volume. The aim of this study was to evaluate the accuracy of Photostimulable Phosphor Plate system with that of conventional film-screen in mandibular pre-implant linear tomography Materials and Methods: In this test eva...

متن کامل

مقایسه سنسورهای دیجیتالی Charge-Coupled Device با Photostimulable Phosphor Storage Plate در تشخیص شکستگی عمودی ریشه در دندان‌های اندو شده (مطالعه آزمایشگاهی)

  Objective: Vertical root fracture (VRF) is among the most common causes of endodontic treatment failures. This study aims to compare charge-coupled devices (CCD) and photostimulable phosphor plates (PSP) for detection of vertical root fractures in endodontically treated teeth.   Methods: In this diagnostic in vitro study, 40 maxillary anterior teeth were selected and after preparation and roo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006