Comparison and verification of bacterial water quality indicator measurement methods using ambient coastal water samples.

نویسندگان

  • John F Griffith
  • Larissa A Aumand
  • Ioannice M Lee
  • Charles D McGee
  • Laila L Othman
  • Kerry J Ritter
  • Kathy O Walker
  • Stephen B Weisberg
چکیده

More than 30 laboratories routinely monitor water along southern California's beaches for bacterial indicators of fecal contamination. Data from these efforts frequently are combined and compared even though three different methods (membrane filtration (MF), multiple tube fermentation (MTF), and chromogenic substrate (CS) methods) are used. To assess data comparability and quantify variability within method and across laboratories, 26 laboratories participated in an intercalibration exercise. Each laboratory processed three replicates from eight ambient water samples employing the method or methods they routinely use for water quality monitoring. Verification analyses also were conducted on a subset of wells from the CS analysis to confirm or exclude the presence of the target organism. Enterococci results were generally comparable across methods. Confirmation revealed a 9% false positive rate and a 4% false negative rate in the CS method for enterococci, though these errors were small in the context of within- and among-laboratory variability. Fecal coliforms also were comparable across all methods, though CS underestimated the other methods by about 10%, probably because it measures only E. coli, rather than the larger fecal coliform group measured by MF and MTF. CS overestimated total coliforms relative to the other methods by several fold and was found to have a 40% false positive rate in verification. Across-laboratory variability was small relative to within- and among-method variability, but only after data entry errors were corrected. One fifth of the laboratories committed data entry errors that were much larger than any method-related errors. These errors are particularly significant because these data were submitted in a test situation where laboratories were aware they would be under increased scrutiny. Under normal circumstances, it is unlikely that these errors would have been detected and managers would have been obliged to issue beach water quality warnings.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of ZnO nanoparticles on the Vibrio species isolated from coastal water of the Persian Gulf port

Introduction: Using zinc oxide nanoparticles, as a catalyst removal of fecal pollution indicator bacteria in water, has been studied as a model of bacterial contamination. This study aims to determine the toxicity and selection of appropriate indicators to evaluate the toxicity of zinc oxide nanoparticles on the isolated bacteria Vibrio species of Bushehr coastal waters. Methods: In this experi...

متن کامل

A Survey on Drinking Water Contamination to Indicator Bacteria in Dairy Farms of Mashhad Suburb

BACKGROUND: Microbial quality of drinking water is very important in animal health. OBJECTIVES: The present survey was conducted to evaluate the microbial quality of cows' drinking water in dairy farms in Mashhad suburb, Iran, to find out defects in this field. METHODS: Water samples were taken from 30 farms and 4 sites including: Water tanks,  inlet and outlet  of bovine drinking troughs and c...

متن کامل

تعیین میزان آلودگی کلیفرم مدفوعی منابع آب برخی روستاهای شهرستان ساری با تست MPN

Background and purpose: Safe drinking is water that does not have any chemical and microbial contamination. According to the World Health Organization (WHO) guideline standards for drinking water total and fecal coliform the indicator of fecal contamination must not be detectable in any 100 ml samples. Pollution indicator bacteria such as coliforms and fecal coliforms were enumerated using a mu...

متن کامل

Comparison of Bacterial Communities in Sands and Water at Beaches with Bacterial Water Quality Violations

Recreational water quality, as measured by culturable fecal indicator bacteria (FIB), may be influenced by persistent populations of these bacteria in local sands or wrack, in addition to varied fecal inputs from human and/or animal sources. In this study, pyrosequencing was used to generate short sequence tags of the 16S hypervariable region ribosomal DNA from shallow water samples and from sa...

متن کامل

Comparison of bacterial indicator analysis methods in stormwater-affected coastal waters.

Membrane filtration (MF) and multiple tube fermentation (MTF) have been used for decades to measure indicator bacteria levels in beach water samples, but new methods based on chromogenic substrate (CS) technology are becoming increasingly popular. Only a few studies have compared results among these methods and they have generally been based on samples collected from a limited number of sites d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Environmental monitoring and assessment

دوره 116 1-3  شماره 

صفحات  -