Pulmonary arterial pulse wave velocity and impedance in man.
نویسندگان
چکیده
Tlie differential pressure method of Womersley and McDonald was used to measure instantaneous blood flow in the main pulmonary artery in ten human subjects. Three subjects had normal pulmonary arterial pressures and flows, seven had mitral stenosis and pulmonary hypertension. The spectrum of input impedance versus frequency was similar to that previously reported for the dog and rabbit, with the modulus decreasing from relatively high values at zero frequency to a minimum between 2 and 5 cycles/sec. Characteristic impedance and phase velocity were lower in the normal subjects than in those with pulmonary hypertension (averages, 23 dyne sec crrr' and 1.68 m/sec in the normals; 46 dyne sec cnr ' and 4.77 m/sec in the hypertensives). Hydraulic energy dissipated per unit time by pulsations in the pulmonary bed was usually higher in the hypertensive than in the normal cases, because of the greater stiffness of the pulmonary arteries in the subjects with pulmonary hypertension. The elasticity of the pulmonary arterial tree appears to be as important as the state of the arterioles and capillaries in determining the energy required for pulsatile pulmonary blood flow. ADDITIONAL
منابع مشابه
An Official Journal of the American Heart Association Pulmonary Arterial Pulse Wave Velocity and Impedance in Man
Tlie differential pressure method of Womersley and McDonald was used to measure instantaneous blood flow in the main pulmonary artery in ten human subjects. Three subjects had normal pulmonary arterial pressures and flows, seven had mitral stenosis and pulmonary hypertension. The spectrum of input impedance versus frequency was similar to that previously reported for the dog and rabbit, with th...
متن کاملPulse wave velocity in the main pulmonary artery of the dog.
Apparent phase velocities in the main pulmonary artery were calculated from simultaneous measurements of pressure at two sites in 11 anesthetized, open-chest dogs, at heart rates ranging from 24 to 240 beat/min. The distribution of apparent phase velocity with harmonic frequency was similar to that reported previously for input impedance and frequency. Phase velocity in the absence of reflectio...
متن کاملNoninvasive (input) impedance, pulse wave velocity, and wave reflection in healthy middle-aged men and women.
The relation between arterial function indices, such as pulse wave velocity and augmentation index with parameters derived from input impedance analysis, is still incompletely understood. Carotid pressure, central flow waveforms, and pulse wave velocity were noninvasively acquired in 2026 apparently healthy, middle-aged subjects (1052 women and 974 men) 35 to 55 years old at inclusion. Input an...
متن کاملEvidence of early degenerative changes in large arteries in human essential hypertension.
Noninvasive evaluation of brachial artery diameter (pulsed Doppler velocimetry) and pulse wave velocity (strain gauge mechanography) was performed in 23 normal subjects and 49 patients with uncomplicated essential hypertension. Pulsatile arterial function was described in terms of derived characteristic impedance and arterial compliance. Compared with normal controls, hypertensive patients had ...
متن کاملارتباط میان سختی شریانی و وضعیت شناختی در سالمندان
Background: Dementia is a common health problem in the elderly. Studies have shown that levels of pulse wave velocity (PWV) could predict cognitive impairment. The objective of this study was assessment of the relationship between arterial stiffness levels and cognitive status among the older people. Methods: In this cross-sectional study, 60 individuals included 31 women and 29 men aged ≥ 60 ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation research
دوره 25 6 شماره
صفحات -
تاریخ انتشار 1969