Sensors on the humerus are not necessary for an accurate assessment of humeral kinematics in constrained movements.

نویسندگان

  • Yin-Liang Lin
  • Andrew R Karduna
چکیده

The measurement of humeral kinematics with a sensor on the humerus is susceptible to large errors due to skin motion artifacts. An alternative approach is to use data from a forearm sensor, combined with data from either a scapular or thoracic sensor. We used three tasks to assess the errors of these approaches: humeral elevation, elbow flexion and humeral internal rotation. Compared with the humeral method, the forearm methods (using either a scapular or thoracic sensor) demonstrated significantly smaller root mean square errors in humeral elevation and humeral internal rotation tasks. Although the errors of the forearm methods were significantly larger than those of the humeral method during elbow flexion, the errors of the forearm methods still were below 3°. Therefore, these forearm methods may be able to accurately measure humeral motion. In addition, since no difference was found between the forearm methods using the scapular or thoracic sensor, it may be possible to accurately assess both shoulder and elbow kinematics with only two sensors: one on the forearm and one on the scapula.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Scapular kinematics in constrained and functional upper extremity movements.

STUDY DESIGN Controlled laboratory study using a single-group, repeated-measures design. OBJECTIVES To investigate scapular kinematics during both constrained and functional shoulder movements. BACKGROUND Abnormal scapulothoracic joint motion has been associated with pathologies such as shoulder impingement. Constrained protocols are commonly used in the measurement of shoulder kinematics; ...

متن کامل

The Outcome of Proximal Humeral Locking Plates in the Management of Three and Four Part Proximal Humeral Fractures in Special Cohort of Young Patients in High Velocity Trauma

Background: Locking plate fixation provides satisfactory outcome following proximal humerus fractures. None of theprevious studies selectively evaluate the outcome in young patients. This study evaluates outcome of locking platesystem in the treatment of acute three- and four-part fractures in young patients.Methods: In this prospective study we included all patients who were less than 60 years...

متن کامل

Wing amputation in a Golden eagle with humeral fracture

Case Description-An adult golden eagle with a wound on its right wing caused by gunshot was presented to the University of Tabriz, Veterinary Teaching Hospital. Clinical Finding-Clinical examination and radiographs, revealed compound fracture in distal third of humerus, severe soft tissue compromise and irreparable loss of blood supply. Anemia and leukocy...

متن کامل

Elbow dislocation with bicondylar humeral fracture in an adult: a unique type of injury

Simultaneous fracture of lateral condyle and medial epicondyle of humerus along with elbow dislocation is very rare injury in adults. Only a few cases have been reported in literature in pediatric age groups. The authors describe a case report of fracture of lateral condyle and medial epicondyle of humerus along with elbow dislocation in a young adult. The patient sustained injury in the form o...

متن کامل

A Pitfall in Fixation of Distal Humeral Fractures with Pre-Contoured Locking Compression Plate

Anatomically precontoured locking plates are intended to facilitate the fixation of articular fractures and particularly those associated with osteoporosis. Fractures of the distal humerus are relatively uncommon injuries where operative intervention can be exceptionally challenging. The distal humeral trochlea provides a very narrow anatomical window through which to pass a fixed-angle locking...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied biomechanics

دوره 29 4  شماره 

صفحات  -

تاریخ انتشار 2013