SAR and temperature: simulations and comparison to regulatory limits for MRI.
نویسندگان
چکیده
PURPOSE To present and discuss numerical calculations of the specific absorption rate (SAR) and temperature in comparison to regulatory limits. While it is possible to monitor whole-body or whole-head average SAR and/or core body temperature during MRI in practice, this is not generally true for local SAR values or local temperatures throughout the body. While methods of calculation for SAR and temperature are constantly being refined, methods for interpreting results of these calculations in light of regulatory limits also warrant discussion. MATERIALS AND METHODS Numerical calculations of SAR and temperature for the human head in a volume coil for MRI at several different frequencies are presented. RESULTS Just as the field pattern changes with the frequency, so do the temperature distribution and the ratio of maximum local SAR (in 1-g or 10-g regions) to whole-head average SAR. In all of the cases studied here this ratio is far greater than that in the regulatory limits, indicating that existing limits on local SAR will be exceeded before limits on whole-body or whole-head average SAR are reached. CONCLUSION Calculations indicate that both SAR and temperature distributions vary greatly with B(1) field frequency, that temperature distributions do not always correlate well with SAR distributions, and that regulatory limits on local temperature may not be exceeded as readily as those on local SAR.
منابع مشابه
Numerical study of RF exposure and the resulting temperature rise in the foetus during a magnetic resonance procedure.
Numerical simulations of specific absorption rate (SAR) and temperature changes in a 26-week pregnant woman model within typical birdcage body coils as used in 1.5 T and 3 T MRI scanners are described. Spatial distributions of SAR and the resulting spatial and temporal changes in temperature are determined using a finite difference time domain method and a finite difference bio-heat transfer so...
متن کاملTemperature and SAR calculations for a human head within volume and surface coils at 64 and 300 MHz.
PURPOSE To examine relationships between specific energy absorption rate (SAR) and temperature distributions in the human head during radio frequency energy deposition in MRI. MATERIALS AND METHODS A multi-tissue numerical model of the head was developed that considered thermal conductivity, heat capacity, perfusion, heat of metabolism, electrical properties, and density. Calculations of SAR ...
متن کاملSAR optimised local B1 + shimming for cardiac imaging at 3T – a multi-model study
Target Audience: This work will benefit those interested in using parallel transmission MRI to reduce SAR in cardiac MR Purpose: Cardiac imaging at high field (3T and above) suffers from image quality issues due to greater B1 + inhomogeneities and is frequently limited by SAR, which constrains the speed at which scans can be run without exceeding regulatory limits. Parallel transmission can mit...
متن کاملDesign and Evaluation of a Hybrid Radiofrequency Applicator for Magnetic Resonance Imaging and RF Induced Hyperthermia: Electromagnetic Field Simulations up to 14.0 Tesla and Proof-of-Concept at 7.0 Tesla
This work demonstrates the feasibility of a hybrid radiofrequency (RF) applicator that supports magnetic resonance (MR) imaging and MR controlled targeted RF heating at ultrahigh magnetic fields (B0≥7.0T). For this purpose a virtual and an experimental configuration of an 8-channel transmit/receive (TX/RX) hybrid RF applicator was designed. For TX/RX bow tie antenna electric dipoles were employ...
متن کاملEEG measurements at 7 Tesla using the Ink Cap
C. E. Vasios, L. M. Angelone, P. Purdon, J. W. Belliveau, G. Bonmassar Athinoula Martinos Center for Biomedical Imaging NMR Center, Charlestown, MA, United States, Biomedical Engineering Department, Tufts University, Medford, MA, United States INTRODUCTION In the few past years there has been an increase in the number of concurrent EEG and fMRI measurements [1][2] and a shift towards higher B0 ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of magnetic resonance imaging : JMRI
دوره 26 2 شماره
صفحات -
تاریخ انتشار 2007