Use of a new plasma scalpel during pulse generator implant and replacement in neuromodulation
نویسندگان
چکیده
Sacral neuromodulation (SNM) is a minimally invasive therapy for defecatory disorders. PEAK Plasma BladeTM (Medtronic) has been used as an alternative to the conventional electric scalpel and scissors in 3 procedures of neuromodulation. PEAK PlasmaBladeTM uses less total energy, operating at significantly lower temperatures than electrosurgical technology. No damage to the wires or pulse generators or patient complications were detected during the surgery or follow-up. A reduction in the duration of the procedures was noted. Subjects: Medicine; Medicine, Dentistry, Nursing & Allied Health; Surgery; Colorectal Surgery
منابع مشابه
Subcapsular relocation for sacral neuromodulation pulse generator implant revision.
OBJECTIVES We describe our technique and experience with subcapsular placement of the Interstim (Medtronic, Minneapolis, MN, USA) pulse generator in cases of revision for implant site pain. METHODS The pulse generator and electrode are carefully exteriorized and the floor of the capsule is incised. The system is placed beneath the floor of the original capsule, which then becomes the roof...
متن کاملSacral Neuromodulation in Patients With a Cardiac Pacemaker
The objective of this study was to describe our experience using sacral neuromodulation to treat urinary urgency, frequency, urge incontinence, and chronic urinary retention in patients with cardiac pacemakers. With the increasingly widespread use of InterStim for bladder function restoration, we are seeing more complex patients with multiple comorbidities, including cardiac conditions. Herein,...
متن کاملDesign and Test of New Robust QCA Sequential Circuits
One of the several promising new technologies for computing at nano-scale is quantum-dot cellular automata (QCA). In this paper, new designs for different QCA sequential circuits are presented. Using an efficient QCA D flip-flop (DFF) architecture, a 5-bit counter, a novel single edge generator (SEG) and a divide-by-2 counter are implemented. Also, some types of oscillators, a new edge-t...
متن کاملTotal Knee Replacement Sizing: Shoe Size Is a Better Predictor for Implant Size than Body Height
Background: Various sizes of implants need to be available during surgery. The purpose of this paper is to comparebody height and shoe size with implant sizes in patients who underwent total knee replacement surgery to see whichbiomarker is a better predictor for preoperative planning to determine implant size.Methods: A total of 100 knees, belonging to 50 females and 50 males, were observed. P...
متن کاملLead stuck (frozen) in header: salvage by bone cutter versus other techniques. [email protected].
It is occasionally difficult to disconnect leads from headers at the time of pulse generator replacement without injuring the fragile leads. Over a 2.5-year period we encountered this problem in six cases (1.7% of pulse generator replacements). The posterior portion of the header was clipped off using an orthopedic bone cutter in four cases. The cut was aligned with the deep end of the lead soc...
متن کامل