Noise levels produced by high-frequency oscillation
نویسندگان
چکیده
for patients with severe respiratory failure. Although the technology has advanced in recent times, the noise levels produced by such devices remain high. Exposure to excessive noise in intensive care may cause hearing problems for both staff and patients following long-term exposure. We investigated the noise level in decibels produced by a SensorMedics 3100B ventilator (SensorMedics, Bilthoven, the Netherlands). Th e maximum total noise level recorded was 85 decibels, with an average of 75 decibels over a 12-hour period. Th ese daily noise levels exceed the minimum required for action to be taken by employers according to regulations operating within the United Kingdom. We suggest three strategies for dealing with this issue that aim to reduce potential harm to both patients and staff . First, reduce the noise produced by oscillators. Th is should be done in conjunction with equipment manufacturers. Second, reduce the potential for damage to patient’s hearing by the provision of ear protection and minimise ototoxic drug use whilst oscillation is employed. Although this may lead to diffi culties in patient communication, in reality those receiving high-frequency oscillation are normally deeply sedated and paralysed. Finally, reduce the risks to staff working with these patient groups. Th e provision of staff ear protection would be problematic, so other strategies should be used. Th ese could include mandatory training, limiting time spent nursing oscillated patients using rotational staffi ng policies, and excluding those with pre-existing hearing problems.
منابع مشابه
Output-only Modal Analysis of a Beam Via Frequency Domain Decomposition Method Using Noisy Data
The output data from a structure is the building block for output-only modal analysis. The structure response in the output data, however, is usually contaminated with noise. Naturally, the success of output-only methods in determining the modal parameters of a structure depends on noise level. In this paper, the possibility and accuracy of identifying the modal parameters of a simply supported...
متن کاملبررسی اثر صدای فرکانس کم بر عملکرد ذهنی
Background and Purpose: Although the evolution of industrial systems toward digital technologies decreased the exposure to high levels of noise, it has created some problems encountered with low level and provoking noise (low frequency noise). In the present work, the mental performance of students exposed to low frequency and reference noises at low and high levels (45 & 65 dB) were studied....
متن کاملارتباط مواجهه همزمان با حلالهای آلی و صدا بر افت شنوایی در فرکانس بالا در کارگران کارخانه لاستیکسازی
Introduction: Based on the results of some studies, concurrent exposure to organic solvents and noise in industrial areas can accelerate the amount of hearing loss. The aim of this study was to assess the effect of concurrent exposure to organic solvents and noise on high frequency hearing loss. Method: This was a cross-sectional analytic study conducted on 1029 tire manufacturing company wo...
متن کاملMitigating Combustion-driven Oscillation (Thermoacoustic Instability) in Industrial Combustors
Combustion processes generate a band-limited pseudo-random sound that is often referred to as “combustion roar.” Although combustion roar sound is moderately intense but it is rather straight forward to quiet to a non-objectionable level by properly applying sound absorbing material around the burner area. In addition to the 'roar' sound which almost always exists in any confined combustion, on...
متن کاملAssessment of the Wavelet Transform for Noise Reduction in Simulated PET Images
Introduction: An efficient method of tomographic imaging in nuclear medicine is positron emission tomography (PET). Compared to SPECT, PET has the advantages of higher levels of sensitivity, spatial resolution and more accurate quantification. However, high noise levels in the image limit its diagnostic utility. Noise removal in nuclear medicine is traditionally based on Fourier decomposition o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 14 شماره
صفحات -
تاریخ انتشار 2010