Automated enzymatic assay for plasma ammonia.

نویسندگان

  • B A Humphries
  • M Melnychuk
  • E J Donegan
  • R D Snee
چکیده

An enzymatic method for determining plasma ammonia with the Du Pont Automatic Clinical Analyzer (aca) is described. The assay requires a sample volume of 500 muL for a kinetic ammonia measurement. The reaction is initiated with glutamate dehydrogenase and the rate of depletion of NADPH is monitored with two measurements, 17 s apart, at 340 nm. Reaction conditions have been optimized for maximum sensitivity through both one-factor-at-a-time and multiple variable response surface optimization techniques. Linearity to 1000 mumol of ammonia per liter of plasma has been achieved. No significant interferences were observed from anticoagulants or endogenous blood components, including pyruvate and oxalacetate. Use of the coenzyme NADPH (instead of NADH) in this aca procedure eliminates the lengthy pre-incubation otherwise required for endogenous dehydrogenase reactions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated enzymatic method for the determination of ammonia: application to rumen fluid, gut fluid, and plasma.

The enzymatic method for the determination of ammonia with glutamate dehydrogenase has been adapted to the AutoAnalyzer. The automated method was applicable for NH(3) measurement in sheep rumen samples, swine gut fluid samples, and bovine plasma. Results were compared with those of the Conway diffusion method and the manual enzymatic method. The automated method allows 30 samples per h to be an...

متن کامل

A step forward in enzymatic measurement of creatinine.

We describe an improved enzymatic ultraviolet absorbance method for assaying creatinine in serum, plasma, and urine. Creatinine is hydrolyzed by creatinine iminohydrolase (EC 3.5.4.21) to ammonia and N-methylhydantoin. The ammonia produced combines with 2-oxoglutarate and NADPH in the presence of glutamate dehydrogenase to yield glutamate and NADP+. The consumption of NADPH, measured by a two-p...

متن کامل

Modified micro-scale enzymatic method for plasma ammonia in newborn and pediatric patients; comparison with a modified cation-exchange procedure.

We modified two "kit" procedures for plasma ammonia to make them suitable for use with newborn and pediatric patients. Available methods either require too large a specimen, are insufficiently sensitive in the normal range, or are too cumbersome. One was an enzymatic (Sigma Chemical Co., St. Louis, Mo. 63178), the other a cation-exchange (Hyland, Costa Mesa, Calif. 92626) method. The modified m...

متن کامل

Automated enzymatic method for determining ammonia in plasma, with 14-day reagent stability.

This is an automated, cost-efficient enzymatic method for determining ammonia in plasma. In most assays for ammonia the reagents are stable for only one or two days at 4 degrees C, but the reagents in our method are stable for at least 14 days. Our method was developed for use with a Cobas-Fara analyzer but can be easily adapted to other automated analyzers. It is essential to use closed sample...

متن کامل

Fixed-time kinetic assay of plasma ammonia, with NADPH as cofactor, with a centrifugal analyzer.

We describe a fixed-time, enzymatic, reaction-rate procedure for determining plasma ammonia with a centrifugal analyzer (Rotochem IIA/36; American Instrument Co., silver Spring, MD 20910), with NADPH as cofactor. The reaction is based on that of da Fonseca-Wollheim's modification [J. Clin. Chem. Clin. Biochem. 11, 421 (1973)] of the Kirstein reaction, which depends on the catalytic amination of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 25 1  شماره 

صفحات  -

تاریخ انتشار 1979