Comparative field study evaluating the activity of recombinant factor VIII Fc fusion protein in plasma samples at clinical haemostasis laboratories
نویسندگان
چکیده
Discrepancies exist for some of the modified coagulation factors when assayed with different one-stage clotting and chromogenic substrate assay reagents. The aim of this study was to evaluate the performance of a recombinant factor VIII Fc fusion protein (rFVIIIFc), currently in clinical development for the treatment of severe haemophilia A, in a variety of one-stage clotting and chromogenic substrate assays in clinical haemostasis laboratories. Haemophilic plasma samples spiked with rFVIIIFc or Advate(®) at 0.05, 0.20 or 0.80 IU mL(-1) were tested by 30 laboratories using their routine procedures and plasma standards. Data were evaluated for intra- and inter-laboratory variation, accuracy and possible rFVIIIFc-specific assay discrepancies. For the one-stage assay, mean recovery was 95% to 100% of expected for both Advate(®) and rFVIIIFc at 0.8 IU mL(-1). Intra-laboratory percent coefficient of variance (CV) ranged from 6.3% to 7.8% for Advate(®), and 6.0% to 10.3% for rFVIIIFc. Inter-laboratory CV ranged from 10% for Advate(®) and 16% for rFVIIIFc at 0.8 IU mL(-1), to over 30% at 0.05 IU mL(-1) for both products. For the chromogenic substrate assay, the average FVIII recovery was 107% ± 5% and 124% ± 8% of label potency across the three concentrations of Advate(®) and rFVIIIFc, respectively. Plasma rFVIIIFc levels can be monitored by either the one-stage or the chromogenic substrate assay routinely performed in clinical laboratories without the need for a product-specific rFVIIIFc laboratory standard. Accuracy by the one-stage assay was comparable to that of Advate(®), while marginally higher results may be observed for rFVIIIFc when using the chromogenic assay.
منابع مشابه
Comparative field study: impact of laboratory assay variability on the assessment of recombinant factor IX Fc fusion protein (rFIXFc) activity.
Due to variability in the one-stage clotting assay, the performance of new factor IX (FIX) products should be assessed in this assay. The objective of this field study was to evaluate the accuracy of measuring recombinant FIX Fc fusion protein (rFIXFc) activity in clinical haemostasis laboratories using the one-stage clotting assay. Human haemophilic donor plasma was spiked with rFIXFc or BeneF...
متن کاملPhysical activity in individuals with haemophilia and experience with recombinant factor VIII Fc fusion protein and recombinant factor IX Fc fusion protein for the treatment of active patients: a literature review and case reports
The World Federation of Hemophilia and the National Hemophilia Foundation encourage people with haemophilia (PWH) to participate in routine physical activity. The benefits of physical activity for PWH include improvements in joint, bone, and muscle health. Accordingly, a number of studies suggest that levels of physical activity among PWH are similar to those of their healthy peers, especially ...
متن کاملA prospective Crossover Triple-blind Controlled Trial on the Safety and Efficacy of Iranian Recombinant FVIII (Safacto) versus Plasma Derived FVIII A pilot study
Background: Considering the increasing number of patients with hemophilia and infrastructure requirements for a comprehensive approach, development of a recombinant factor has become a milestone. The objective of this study was to assess the safety, efficacy and non inferiority of Safacto (Recombinant factor VIII) compared with plasma-derived factor in the treatment of hemophilia A. Methods: 10 ...
متن کاملEvaluation of recombinant factor VIII Fc (Eloctate) activity by thromboelastometry in a multicenter phase 3 clinical trial and correlation with bleeding phenotype
: The aim of this study was to compare the hemostatic efficacy of recombinant factor VIII Fc (rFVIIIFc) (Eloctate) and Advate by ex-vivo rotation thromboelastometry (ROTEM) of whole blood and to explore potential ROTEM parameters that may be more predictive of a patient's bleeding tendency than plasma FVIII activity. Thirteen clinical sites were selected to perform ROTEM on freshly collected bl...
متن کاملCLINICAL TRIALS AND OBSERVATIONS Safety and prolonged activity of recombinant factor VIII Fc fusion protein in hemophilia A patients
Current factor VIII (FVIII) products display a half-life (t1/2) of 8-12 hours, requiring frequent intravenous injections for prophylaxis and treatment of patients with hemophilia A. rFVIIIFc is a recombinant fusion protein composed of a single molecule of FVIII covalently linked to the Fc domain of human IgG1 to extend circulating rFVIII t1/2. This first-in-human study in previously treated sub...
متن کامل