A three-dimensional articulatory model of the velum and nasopharyngeal wall based on MRI and CT data.

نویسندگان

  • Antoine Serrurier
  • Pierre Badin
چکیده

An original three-dimensional (3D) linear articulatory model of the velum and nasopharyngeal wall has been developed from magnetic resonance imaging (MRI) and computed tomography images of a French subject sustaining a set of 46 articulations, covering his articulatory repertoire. The velum and nasopharyngeal wall are represented by generic surface triangular meshes fitted to the 3D contours extracted from MRI for each articulation. Two degrees of freedom were uncovered by principal component analysis: first, VL accounts for 83% of the velum variance, corresponding to an oblique vertical movement seemingly related to the levator veli palatini muscle; second, VS explains another 6% of the velum variance, controlling a mostly horizontal movement possibly related to the sphincter action of the superior pharyngeal constrictor. The nasopharyngeal wall is also controlled by VL for 47% of its variance. Electromagnetic articulographic data recorded on the velum fitted these parameters exactly, and may serve to recover dynamic velum 3D shapes. The main oral and nasopharyngeal area functions controlled by the articulatory model, complemented by the area functions derived from the complex geometry of each nasal passage extracted from coronal MRIs, were fed to an acoustic model and gave promising results about the influence of velum movements on the spectral characteristics of nasals.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Application of computed tomography and magnetic resonance imaging fusion images for delineating gross tumor volume in three-dimensional conformal radiotherapy of nasopharyngeal carcinoma

Background: To evaluate computed tomography (CT) and magnetic resonance imaging (MRI) fusion images for delineating gross tumor volume (GTV) in three-dimensional conformal radiotherapy (3D-CRT) of nasophanrygeal carcinoma (NPC), and compare treatment outcomes between CT- and CT+MRI-based targets. Materials and Methods: A total of 120 NPC patients treated with 3D-CRT were included, in which, 60 ...

متن کامل

A three-dimensional linear articulato MRI data

In the framework of studies on nasality, we have attempted to develop a 3-D articulatory model of velum. Sets of 25 sagittal MRI images have been collected for one French subject sustaining 46 articulations. Contours of the velum have been manually drawn from these images; a common 3-D triangular mesh has then been fitted to these contours in order to constitute 3-D representations of the velum...

متن کامل

Towards a 3D articulatory model of velum based on MRI and CT images

This paper describes the processing of MRI and CT images needed for developing a 3D linear articulatory model of velum. The 3D surface that defines each organ constitutive of the vocal and nasal tracts is extracted from MRI and CT images recorded on a subject uttering a corpus of artificially sustained French vowels and consonants. First, the 2D contours of the organs have been manually extract...

متن کامل

Radiobiological Model-Based Comparison of Three-Dimensional Conformal and Intensity-Modulated Radiation Therapy Plans for Nasopharyngeal Carcinoma

Introduction: Radiobiological modeling of radiotherapy plans are used for treatment plan comparisons. The current study aimed to compare the three-dimensional conformal radiation therapy (3DCRT) and intensity-modulated radiation therapy (IMRT) plans for nasopharyngeal cancer using radiobiological modeling. Materials and Methods: This study was conducted on 10 patients with nasopharyngeal carci...

متن کامل

Fabrication of New 3D Phantom for Measuring Geometric Distortion in Magnetic Resonance Imaging System

  Introduction: Geometric distortion is a major shortcoming of magnetic resonance imaging (MRI), which has an important influence on the accuracy of volumetric measurements, an important parameter in neurology and oncology. Our goal is to design and construct a new three- dimensional phantom using a 3D printer in order to measure geometric distortion and its reproducibility in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of the Acoustical Society of America

دوره 123 4  شماره 

صفحات  -

تاریخ انتشار 2008