Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry interlaboratory comparison of mixtures of polystyrene with different end groups: statistical analysis of mass fractions and mass moments.

نویسندگان

  • Charles M Guttman
  • Stephanie J Wetzel
  • Kathleen M Flynn
  • Bruno M Fanconi
  • David L VanderHart
  • William E Wallace
چکیده

A matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) interlaboratory comparison was conducted on mixtures of synthetic polymers having the same repeat unit and closely matching molecular mass distributions but with different end groups. The interlaboratory comparison was designed to see how well the results from a group of experienced laboratories would agree on the mass fraction, and molecular mass distribution, of each polymer in a series of binary mixtures. Polystyrenes of a molecular mass near 9000 u were used. Both polystyrenes were initiated with the same butyl initiator; however, one was terminated with -H (termed PSH) and the other was terminated with -CH2CH2OH (termed PSOH). End group composition of the individual polymers was checked by MALDI-TOF MS and by nuclear magnetic resonance (NMR). Five mixtures were created gravimetrically with mass ratios between 95:5 and 10:90 PSOH/PSH. Mixture compositions where measured by NMR and by Fourier transform infrared spectrometry (FT-IR). NMR and FT-IR were used to benchmark the performance of these methods in comparison to MALDI-TOF MS. Samples of these mixtures were sent to any institution requesting it. A total of 14 institutions participated. Analysis of variance was used to examine the influences of the independent parameters (participating laboratory, MALDI matrix, instrument manufacturer, TOF mass separation mode) on the measured mass fractions and molecular mass distributions for each polymer in each mixture. Two parameters, participating laboratory and instrument manufacturer, were determined to have a statistically significant influence. MALDI matrix and TOF mass separation mode (linear or reflectron) were found not to have a significant influence. Improper mass calibration, inadequate instrument optimization with respect to high signal-to-noise ratio across the entire mass range, and poor data analysis methods (e.g., baseline subtraction and peak integration) seemed to be the greatest obstacles in the correct application of MALDI-TOF MS to this problem. Each of these problems can be addressed with proper laboratory technique.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

NIST-Sponsored Interlaboratory Comparison of Polystyrene Molecular Mass Distribution Obtained by Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry: Statistical Analysis

The method of preparation and methods of analysis of a narrow distribution polystyrene of ∼7 ku used in an interlaboratory comparison of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) of synthetic polymers is described. Size exclusion chromatography was used to measure the polystyrene sample variability. Fourier transform infrared spectroscopy and MA...

متن کامل

Certification of a Polystyrene Synthetic Polymer, SRM 2888

The certification of a polystyrene standard reference material, SRM 2888, is described. The Mw of SRM 2888 was determined by light scattering to be 7.19x10 g/mol with a sample standard deviation of 0.14 x10 g/mol. A combined expanded uncertainty for this light scattering Mw determination, including systematic and random uncertainties, was estimated to be 0.57 x10 g/mol. Mn was determined by nuc...

متن کامل

Design, Construction and Calibration of a Laser Ionization Time-of-Flight Mass Spectrometer

A time-of-flight mass spectrometer (TOF-MS) developed in our laboratory at Isfahan University of Technology is described here. The TOF-MS instrument uses laser as the ionization source which provides an opportunity to investigate the ions formed in laser ablation or desorption. The TOF-MS has an ionization chamber containing an accelerator and an ion lens to focus the ions into a one meter line...

متن کامل

Coupling thermal field-flow fractionation with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry for the analysis of synthetic polymers.

Thermal field-flow fractionation (ThFFF) and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) have been coupled to yield a powerful combination of techniques for polymer analysis. Thermal FFF's high molecular weight (MW) selectivity and sensitivity to chemical composition are used to separate polydisperse polymers and polymer mixtures into the narrow po...

متن کامل

Matrix-assisted ultraviolet laser-desorption ionization time-of-flight mass spectrometry of sulfated mannans from the red seaweed Nothogenia fastigiata.

Matrix-assisted ultraviolet laser-desorption ionization time-of-flight mass spectrometry (UV-MALDI-TOF-MS) was applied to sulfated xylo-mannan fractions from Nothogenia fastigiata in order to determine their molecular weights and distribution profiles. The number-average molecular weight calculated from the spectra was similar to that determined by chemical end-group analysis for the lower mole...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 77 14  شماره 

صفحات  -

تاریخ انتشار 2005