Importance of preclinical evaluation of wear in hip implant designs using simulator machines☆
نویسندگان
چکیده
Total hip arthroplasty (THA) is a surgical procedure that involves the replacement of the damaged joint of the hip by an artificial device. Despite the recognized clinical success of hip implants, wear of the articulating surfaces remains as one of the critical issues influencing performance. Common material combinations used in hip designs comprise metal-on-polymer (MoP), ceramic-on-polymer (CoP), metal-on-metal (MoM), and ceramic-on-ceramic (CoC). However, when the design of the hip implant is concerned besides the materials used, several parameters can influence its wear performance. In this scenario, where the safety and efficacy for the patient are the main issues, it is fundamental to evaluate and predict the wear rate of the hip implant design before its use in THA. This is one of the issues that should be taken into account in the preclinical evaluation step of the product, in which simulated laboratory tests are necessary. However, it is fundamental that the applied motions and loads can reproduce the wear mechanisms physiologically observed in the patient. To replicate the in vivo angular displacements and loadings, special machines known as joint simulators are employed. This article focuses on the main characteristics related to the wear simulation of hip implants using mechanical simulators, giving information to surgeons, researchers, regulatory bodies, etc., about the importance of preclinical wear evaluation. A critical analysis is performed on the differences in the principles of operation of simulators and their effects on the final results, and about future trends in wear simulation.
منابع مشابه
Finite Element Analysis of Different Hip Implant Designs along with Femur under Static Loading Conditions
Background: The hip joint is the largest joint after the knee, which gives stability to the whole human structure. The hip joint consists of a femoral head which articulates with the acetabulum. Due to age and wear between the joints, these joints need to be replaced with implants which can function just as a natural joint. Since the early 19th century, the hip joint arthroplasty has evolved, a...
متن کاملInfluence of hip joint simulator design and mechanics on the wear and creep of metal-on-polyethylene bearings
Hip joint simulators are used extensively for preclinical testing of hip replacements. The variation in simulator design and test conditions used worldwide can affect the tribological performance of polyethylene. The aim of this study was to assess the effects of simulator mechanics and design on the wear and creep of ultra-high-molecular-weight polyethylene. In the first part of this study, an...
متن کاملRetrieval Research in Hip and Knee Arthroplasty
During the last two decades, improvements in hip and knee designs, bearing materials, sterilisation techniques, oxidation stabilisation, and articulating surface treatments have led to superior performance of total hip and knee arthroplasties by reducing the prevalence of wear, delamination, and structural material fatigue. These advances are expected to show substantial benefits in decreasing ...
متن کاملAcetabular Cups in 60 mm Metal-on-Metal Bearings Subjected to Dynamic Edge-Loading with 70 Peak-Inclination in 10-Million Cycle Simulator Study
Wear simulation of total-hip arthroplasty (THA) involves hip biomechanics, tribology, bearing designs and cup wear-patterns. This is the first demonstration of cup edge-loading using the “Inverted-cup” test mode. Benefits included, (i) clinically relevant wear-patterns, and (ii) cup inclinations varying from ideal to edge-loaded during each 1-s simulator cycle. The 60 mm head and cup bearings i...
متن کاملSlide track analysis of eight contemporary hip simulator designs.
In an earlier paper, the authors presented a new method of computation of slide tracks in the relative motion between femoral head and acetabular cup of total hip prostheses. For the first time, computed tracks were verified experimentally and with an alternative method of computation. Besides being an efficient way to illustrate hip kinematics, the shapes of the slide tracks are known to be of...
متن کامل