Experimental measures of ventricular activation and synchrony.
نویسندگان
چکیده
BACKGROUND A widened QRS complex as a primary indication for cardiac resynchronization therapy (CRT) for heart failure patients has been reported to be an inconsistent indicator for dyssynchronous ventricular activation. The purpose of this study was to conduct a detailed experimental investigation of total ventricular activation time (TVAT), determine how to measure it accurately, and compare it to the commonly used measure of QRS width. In addition, we investigated a measure of electrical synchrony and determined its relationship to the duration of ventricular activation. METHODS Unipolar electrograms (EGs) were recorded from the myocardial volume using plunge needle electrodes, from the epicardial surface using "sock" electrode arrays, and from the surface of an electrolytic torso-shaped tank. EGs were analyzed to determine a root mean square (RMS)-based measure of ventricular activation and electrical ventricular synchrony. RESULTS The RMS-based technique provided an accurate means of measuring TVAT from unipolar EGs recorded from the heart, the entire tank surface, or the precordial leads. In normal canine hearts, a quantification of ventricular electrical synchrony (VES) for normal ventricular activation showed that the ventricles activate, on average, within 3 ms of each other with the left typically activating first. CONCLUSION Conclusions from this study are: (1) ventricular activation was reflected accurately by the RMS width obtained from direct cardiac measurements and from precordial leads on the tank surface and (2) VES was not strongly correlated with TVAT.
منابع مشابه
Frontiers in congestive heart failure: Ventricular contraction abnormalities in dilated cardiomyopathy: effect of biventricular pacing to correct interventricular dyssynchrony.
OBJECTIVE To measure ventricular contractile synchrony in patients with dilated cardiomyopathy (DCM) and to evaluate the effects of biventricular pacing on contractile synchrony and ejection fraction. BACKGROUND Dilated cardiomyopathy is characterized by abnormal ventricular activation and contraction. Biventricular pacing may promote a more coordinated ventricular contraction pattern in thes...
متن کاملAge- and sex-based reference limits and clinical correlates of myocardial strain and synchrony: the Framingham Heart Study.
BACKGROUND There is rapidly growing interest in applying measures of myocardial strain and synchrony in clinical investigations and in practice; data are limited regarding their reference ranges in healthy individuals. METHODS AND RESULTS We performed speckle-tracking-based echocardiographic measures of left ventricular myocardial strain and synchrony in healthy adults (n=739, mean age 63 yea...
متن کاملElectrical and mechanical components of dyssynchrony in heart failure patients with normal QRS duration and left bundle-branch block: impact of left and biventricular pacing.
BACKGROUND Resynchronization pacing is an effective symptomatic treatment for heart failure patients with prolongation of the QRS duration (QRSd). Dyssynchronous contraction of the left ventricle is also observed with normal QRSd. We set out to determine how electrical activation of the left ventricular (LV) free wall differed between patients with left bundle-branch block (LBBB) and normal QRS...
متن کاملEndocardial versus epicardial electrical synchrony during LV free-wall pacing.
Cardiac resynchronization therapy has been most typically achieved by biventricular stimulation. However, left ventricular (LV) free-wall pacing appears equally effective in acute and chronic clinical studies. Recent data suggest electrical synchrony measured epicardially is not required to yield effective mechanical synchronization, whereas endocardial mapping data suggest synchrony (fusion wi...
متن کاملImpact of transcatheter pulmonary valve replacement on biventricular strain and synchrony assessed by cardiac magnetic resonance feature tracking.
BACKGROUND Transcatheter pulmonary valve (TPV) replacement is an emerging therapy intended to restore pulmonary valve function in patients with right ventricular outflow tract conduit dysfunction; the impact of this technique on ventricular strain and synchrony is not known. METHODS AND RESULTS Cardiac magnetic resonance and ECG data acquired at 1 center as part of the US Melody TPV trial wer...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Pacing and clinical electrophysiology : PACE
دوره 31 12 شماره
صفحات -