Continuous-flow determination of primary bile acids, by bioluminescence, with use of nylon-immobilized bacterial enzymes.
نویسندگان
چکیده
We describe a continuous-flow bioluminescence method for measuring primary bile acid in serum, with nylon as the solid support. 7 alpha-Hydroxysteroid dehydrogenase (EC 1.1.1. 159), a bacterial luciferase (EC 1.14.14.3), and NAD+:FMN oxido-reductase (EC 1.6.8.1) are covalently co-immobilized on a nylon coil (1 m X 1.0 mm i.d.). The assay is highly specific for 7 alpha-hydroxy bile acids. Other bile acids and steroids do not interfere. The continuous-flow light-emitting system, in which the reactor (nylon coil) is placed in front of a photomultiplier tube inside a luminometer, is versatile and simple. The flow is air-segmented, and serum samples (5-50 microL) can be injected directly. Concentration and response are linearly related from 10 to 2500 pmol per assay tube. The precision of the method is satisfactory (CV 5-10%), both inter- and intra-assay. We validated the technique by comparing results with those by RIA, enzyme immunoassay, and "high-performance" liquid chromatography. More than 20 samples an hour can be analyzed, with no carryover. The nylon-immobilized enzymes are stable for more than two months, and greater than 500 samples can be analyzed with use of a few milligrams of enzymes. Normal values for bile acid content of serum ranged from 1 to 2.5 mumol/L, in agreement with those obtained by other methods.
منابع مشابه
Bioluminescence measurement of primary bile acids using immobilized 7 alpha-hydroxysteroid dehydrogenase: application to serum bile acids.
A simple, rapid, and sensitive bioluminescence method for measuring primary bile acids has been developed and validated. The method is based on enzymatic dehydrogenation of bile acids using a bacterial 7 alpha-hydroxysteroid dehydrogenase that is co-immobilized on Sepharose 4B beads with NADH:FMN oxidoreductase and a bacterial luciferase. The assay is specific for 7 alpha-hydroxy bile acids and...
متن کاملSingle- and coupled-enzyme nylon-tube reactors for plasma glucose determination with glucose oxidase and aldehyde dehydrogenase.
We describe routine methods for determining glucose in plasma with use of aldehyde dehydrogenase or glucose oxidase-aldehyde dehydrogenase immobilized in a nylon tube that is integrated into a continuous-flow system. Although the coupled-enzyme nylon-tube reactors require the presence of a third enzyme, catalase, in solution, the kinetics are not so complicated as to preclude reliable routine d...
متن کاملSingle- and coupled-enzyme nylon tube reactors for routine determination of pyruvate and lactate in serum.
We describe the use of a continuous-flow clinical analyzer with an immobilized coupled-enzyme nylon tube reactor and an immobilized single-enzyme nylon tube reactor for routine estimation of lactate and pyruvate in serum. These reactors are incorporated into the flow system of a modified continuous-flow analyzer (Technicon AutoAnalyzer). Results for serum lactate and pyruvate by this method are...
متن کاملImmobilized-enzyme nylon-tube reactors for routine determination of urea and citrulline in serum.
A continuous-flow clinical analyzer for the routine estimation of urea is described that makes use of an immobilized-enzyme nylon-tube reactor as part of a flow-through system (a Technicon AutoAnalyzer I). Results of blood-urea analyses by use of the immobilized urease are compared with determinations made with the diacetyl monoxime method and the urease solution method. Clinical trials carried...
متن کاملLuminescent Techniques Applied to Bioanalysis
The bioand chemiluminescent reagents, introduced in analytical chemistry since the seventies, allow amplification of the analytical signál and to develop fast and sensitive methods. The bioluminescent enzymatic systems based on firefly or bacterial luciferase, the chemiluminescent emission of the hydrogen peroxide/peroxidase/luminol systém or some more recently introduced luminescent substrates...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 30 2 شماره
صفحات -
تاریخ انتشار 1984