Plasma vitamin A assay by fluorometry and use of a silicic acid column technique.

نویسندگان

  • P J Garry
  • J D Pollack
  • G M Owen
چکیده

We investigated a new procedure in which silicic acid column chromatography and fluorometry are used to assay plasma vitamin A. Using tntium-labeled vitamin A acetate and vitamin A alcohol as radioactive stan. dards, we identified two fluorescent components in plasma extracts chromatographed on silicic acid columns. One unidentified fluorescent component was eluted first with hexane or petroleum ether. Vitamin A, the second fluorescent peak, was quantitatively eluted with isopropanol. The isopropanol eluates could be immediately assayed fluorometrically without further treatment. The unidentified compound was sensitive to ultraviolet irradiation, which destroyed it slower than vitamin A is destroyed. Values correlated well for plasma vitamin A concentrations, determined by this procedure and by the Neeld and Pearson modification of the Carr-Price colorimetnic method (r = 0.871). By our technique, we found 34 g of vitamin A per 100ml of plasma in 778preschool children.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assay for plasma 25-hydroxyvitamin D2 and 25-hydroxyvitamin D3 by "high-performance" liquid chromatography.

We describe a new, rapid, and simple column-chromatographic procedure for 25-OH vitamin D3 in plasma. The vitamin is extracted by use of Sep-pak C18 (octadecyl alkylated silicic acid), a short factory-packed reversed-phase column, and 25-OH vitamin D2 + 25-OH vitamin D3 fraction is eluted with methanol/water. The 25-OH D2 and 25-OH D3 are then well resolved on a high-resolution 3-micrometer sil...

متن کامل

Serum gentamicin assay by high-performance liquid chromatography.

We describe a high-performance liquid chromatographic method for the quantitative determination of gentamicin in serum. The antibiotic was separated from serum by passage through a silicic acid column, derivatized with o-phthalaldehyde, and eluted with ethanol. The derivatized gentamicin was then separated into all three of its major components by reversed-phase chromatography and quantified by...

متن کامل

A High-Performance Liquid Chromatographic Assay for the Determination of Losartan in Plasma

A rapid and sensitive HPLC method was developed for determination of losartan in plasma. Losartan was extracted from plasma by a two-step extraction procedure using chloroform as extracting solvent in acidic medium. HPLC analysis was performed on a cyano reversed-phase column using phosphate buffer (pH 4.3), acetonitrile (750:250, v/v) as mobile phase with a flow rate of 0.9 mL/min. Sodium dicl...

متن کامل

Method validation of methotrexate in human plasma by LC-MS technique in patients with brain tumor.

Background and aims: A selective and sensitive high performance liquid chromatography-electrospray ionization mass spectrometry method has been established for determination of methotrexate in human plasma. Methods: Methotrexate was extracted from plasma with acetonitrile. The mobile phase consisted of acetonitrile-water-formic acid 74: 25: 1(v/v). Twenty...

متن کامل

Method validation of clonidine hydrochloride in human plasma by LC-MS technique

A simple and sensitive high performance liquid chromatography-electrospray ionization mass spectrometry method has been evaluated for the assignment of clonidine hydrochloride in human plasma. The mobile phase composed of acetonitrile–water 60:40 (v/v), and 0.2% formic acid 20 µL of sample was chromatographically analyzed using a repacked ZORBAX-XDB-ODS C18 column (2.1 mm×30 m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 16 9  شماره 

صفحات  -

تاریخ انتشار 1970