Effect of Contamination on Electric Field Distribution of DC Voltage Divider
نویسندگان
چکیده
In order to research the influence of the contamination around the external insulating surface of DC voltage divider with different types in the electic field distribution by using the finite element method, a two dimensional axisymmetric model of the DC voltage divider in Longquan convertor station is built. Through the calculation comparison in electrostatic and quasi-electrostatic field, the relative dielectric constant of the dry, moist and the non-uniform mixed contamination layer is discussed under the condition of the material parameters is known in quasi-electrostatic field. Analysis shows that for dry contamination, the field type has no influence on the electric field distribution when the parameters of the materials are same. While for moist contamination, the relative dielectric constant in electrostatic field should be set according to the material resistivity in quasi-electrostatic field and the actual condition. The calculation of the non-uniform contamination prove that the materials parameters in electrostatic filed is reasonable.
منابع مشابه
Effects of Disc Insulator Type and Corona Ring on Electric Field and Voltage Distribution over 230-kV Insulator String by Numerical Method
Insulator strings with several material and profiles are very common in overhead transmission lines. However, the electric field and voltage distribution of insulator string is uneven which may easily lead to corona, insulators’ surface deterioration and even flashover. So the calculation of the electric field and voltage distribution along them is a very important factor in the operation time....
متن کاملAn Experimental Study of the Effect of High Electric Field on Mass Transfer Enhancement
Applying corona wind as a novel technique can lead to a great level of heat and mass transfer augmentation by using a very small amount of energy. The enhancement of forced flow evaporation rate by applying electric field (corona wind) has been experimentally evaluated in this study. Corona wind produced by a fine wire electrode charged with positive high DC voltage impinges on water surface an...
متن کاملAnalysis of Grading Ring Design Parameters and Heat Sink Numbers Effect on Voltage Distribution and Leakage Current in Metal Oxide Surge Arrester
Metal oxide surge arresters (ZNO) are used widely in power system to protect equipments from over voltages. Non uniform potential distribution leads to the depressed service life and low safe reliability, so grading ring is applied on HV surge arrester order to uniform the electric field distribution. One of the problems of arresters is leakage current in power frequency that different paramet...
متن کاملEffect of Cell Size and Shape on Electric Field Threshold and Critical Transmembrane Voltage for Electroporation
Introduction: Electroporation is a technique for increasing the permeability of the cell membrane to otherwise non-permeate molecules due to an external electric field. This permeability enhancement is detectable if the induced transmembrane voltage becomes greater than a critical value which depends on the pulse strength threshold. In this study, the variabil...
متن کاملDetermination of Electric Field at Inception Based upon Current-Voltage Characteristics of AC Corona in Rod-Plane Gaps
This paper deals with the measurement of AC corona inception voltage, Vincp, at the tip of a rod electrode using a hemispherically-capped rod-plane electrode configuration for various rod radii with a short air gap. Effects of atmospheric pressure and temperature variation on Vincp are investigated experimentally. An empirical equation for the field form factors of the hemispherically cappe...
متن کامل