Tropospheric Emission Spectrometer nadir spectral radiance comparisons

نویسندگان

  • Mark W. Shephard
  • Helen M. Worden
  • Karen E. Cady-Pereira
  • Michael Lampel
  • Mingzhao Luo
  • Kevin W. Bowman
  • Edwin Sarkissian
  • Reinhard Beer
  • David M. Rider
  • David C. Tobin
  • Henry E. Revercomb
  • Brendan M. Fisher
  • Denis Tremblay
  • Shepard A. Clough
  • Gregory B. Osterman
  • Michael Gunson
چکیده

[1] The fundamental measurement of the Tropospheric Emission Spectrometer (TES) on board the Aura spacecraft is upwelling infrared spectral radiances. Accurate TES retrievals of surface and atmospheric parameters such as trace gas amounts critically depend on well-calibrated radiance spectra. On-orbit TES nadir observations were evaluated using carefully selected, nearly coincident spectral radiance measurements from Atmospheric Infrared Sounder (AIRS) on Aqua and special scanning high-resolution interferometer sounder (SHIS) underflights. Modifications to the L1B calibration algorithms for TES version 2 data resulted in significant improvements for the TES-AIRS comparisons. The comparison of TES with SHIS (adjusted for geometric differences) show mean and standard deviation differences of less than 0.3 K at warmer brightness temperatures of 290–295 K. The TES/SHIS differences are less than 0.4 K at brightness temperatures of 265–270 K. There are larger TES/SHIS comparison differences for higher-frequency TES 1A1 filter, which has less upwelling radiance signal. The TES/ AIRS comparisons show mean differences of less than 0.3 K at 290–295 K and less than 0.5 K at 265–270 K with standard deviation less than 0.6 K for the majority of the spectral regions and brightness temperature range. A procedure to warm up the optical bench for better alignment in December 2005 gave a fourfold increase in the signalto-noise ratio at higher frequency ranges. Recent results from a long-term comparison of TES sea surface temperature (SST) observations with the Reynolds optimally interpolated (ROI) SST product demonstrates TES radiometric stability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Measurements of SO[2] profiles in volcanic plumes from the NASA Tropospheric Emission Spectrometer (TES)

[1] Satellite measurements are now recognized as a key element for the early detection and characterization of volcanic eruptions, in particular in the context of aircraft routing. A common tracer of volcanic plumes is sulfur dioxide (SO2), which so far has been measured by ultraviolet-visible (UV-vis) instruments and multispectral infrared (IR) sounders. Here we report the first SO2 vertical p...

متن کامل

Implementation of cloud retrievals for Tropospheric Emission Spectrometer (TES) atmospheric retrievals: part 1. Description and characterization of errors on trace gas retrievals

[1] We develop an approach to estimate and characterize trace gas retrievals in the presence of clouds in high spectral measurements of upwelling radiance in the infrared spectral region (650–2260 cm ). The radiance contribution of clouds is parameterized in terms of a set of frequency-dependent nonscattering optical depths and a cloud height. These cloud parameters are retrieved jointly with s...

متن کامل

Nadir measurements of carbon monoxide distributions by the Tropospheric Emission Spectrometer instrument onboard the Aura Spacecraft: Overview of analysis approach and examples of initial results

[1] We provide an overview of the nadir measurements of carbon monoxide (CO) obtained thus far by the Tropospheric Emission Spectrometer (TES). The instrument is a high resolution array Fourier transform spectrometer designed to measure infrared spectral radiances from low Earth orbit. It is one of four instruments successfully launched onboard the Aura platform into a sun synchronous orbit at ...

متن کامل

Satellite measurements of the clear-sky greenhouse effect from tropospheric ozone

Radiative forcing from anthropogenic ozone in the troposphere is an important factor in climate change, with an average value of 0.35 W m according to the Intergovernmental Panel for Climate Change (IPCC). IPCC model results range from 0.25 to 0.65 W m, owing to uncertainties in the estimates of pre-industrial concentrations of tropospheric ozone, and in the present spatial and temporal distrib...

متن کامل

Predicted errors of tropospheric emission spectrometer nadir retrievals from spectral window selection

[1] Error covariances and vertical resolutions are reported for Tropospheric Emission Spectrometer (TES) nadir-view retrievals of surface temperature, atmospheric temperature, H2O, O3, CO, and CH4. These error covariances are computed as a result of selecting spectral windows that maximize the information content of simulated, TES nadir-view atmospheric retrievals of four regions representative...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008