A novel sternal closure technique with implants suitable for complex dehiscences.
نویسندگان
چکیده
A novel sternum stabilization implant system is presented in a complex clinical case with previous pseudarthroses. The authors used the advanced closure system Sternal Talon of KLS Martin group and arranged 1 double and 2 single implants in an atypical fashion to fit the patient's needs. One year later follow up has not revealed any recurrence of pain or pseudarthrotic signs such as crepitation.
منابع مشابه
A new cable-tie based sternal closure system: description of the device, technique of implantation and first clinical evaluation
BACKGROUND Wire closure still remains the preferred technique despite reasonable disadvantages. Associated complications, such as infection and sternal instability, cause time- and cost-consuming therapies. We present a new tool for sternal closure with its first clinical experience and results. METHODS The sternal ZipFix(TM) System is based on the cable-tie principle. It primarily consists o...
متن کاملPrimary Closure of A Sternal Cleft in A Neonate
A three day old neonate was referred to our department with a problem of a sternal cleft. Sternal clefts are often associated with a myriad of other abnormalities ranging from mild to severe. We present our experience with such a problem, and review the current literature concerning it.
متن کاملEvaluation of Sternal Closure with Absorbable Polydioxanone Sutures in Children
INTRODUCTION Sternal dehiscence, sternal wound infection and mediastinitis are troublesome complications following median sternotomy which are major causes of morbidity and mortality of patients. Synthetic polydioxanone absorbable suture seems effective in prevention of these complications in children undergoing open heart surgery. METHODS During 2 years period, 620 patients who underwent med...
متن کاملInitial experience with a technique for wound closure after cardiac device implantation designed to reduce infection and minimize tissue scar formation.
Infection is a well-recognized complication that can occur after the implantation of cardiac devices such as pacemakers and implantable cardioverter defibrillators (ICDs). Reported infection rates after new device implantation are reported to be around 1%, while infection rates after device generator replacements are higher with a reported average of up to 4-5% per year. Here we report our expe...
متن کاملNitinol flexigrip sternal closure system and chest wound infections: insight from a comparative analysis of complications and costs.
BACKGROUND We sought to assess the efficiency of two different sternal closure techniques in preventing sternal wound complications (SWC). A cost analysis was also considered. METHODS Between January 2008 and April 2010, 1,644 consecutive cardiac surgery patients who underwent cardiac surgery in our institute were prospectively collected. A total of 1,072 patients received a standard paraster...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Surgical innovation
دوره 17 4 شماره
صفحات -
تاریخ انتشار 2010