Factors affecting bony impingement in hip arthroplasty.

نویسندگان

  • William B Kurtz
  • Timo M Ecker
  • William M Reichmann
  • Stephen B Murphy
چکیده

Computer modeling of 10 patients' computed tomographic scans was used to study the variables affecting hip arthroplasty range of motion before bony impingement (ROMBI) including acetabular offset and height, femoral offset, height and anteversion, and osteophyte removal. The ROMBI was compared with the ROM before component impingement and the native hip ROM. The ROMBI decreased with decreased total offset and limb shortening. Acetabular offset and height had a greater effect on ROMBI than femoral offset and height. The ROMBI lost with decreased acetabular offset was not fully recoverable with an increase in femoral offset or osteophyte removal. Bony impingement increased and component impingement decreased with decreased acetabular offset and increased head diameter.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Bony Impingement in Regard to Internal Rotation Limit after Total Hip Arthroplasty Using Rotation Matrix

OBJECTIVES Bony impingement of the proximal femur on the pelvis is an important factor for dislocation after total hip arthroplasty (THA). We evaluated bony impingement after THA using the rotation matrix derived from postoperative computed tomography (CT) images. PATIENTS AND METHODS One hundred and seven hip joints were subjected to primary THA via a posterolateral approach. We used the rot...

متن کامل

Development and evaluation of an image-free computer-assisted impingement detection technique for total hip arthroplasty.

Periprosthetic or bony impingement in total hip arthroplasty (THA) has been correlated to dislocation, increased wear, reduced postoperative functionality with pain and/or decreased range of motion (ROM). We sought to study the accuracy and assess the reliability of measuring bony and periprosthetic impingement on a virtual bone model prior to the implantation of the acetabular cup with the hel...

متن کامل

Sexual activity after total hip arthroplasty: a motion capture study.

Relative risk of impingement and joint instability during sexual activities after total hip arthroplasty (THA) has never been objectively investigated. Hip range of motion necessary to perform sexual positions is unknown. A motion capture study with two volunteers was performed. 12 common sexual positions were captured and relevant hip joint kinematics calculated. The recorded data were applied...

متن کامل

Dual poly liner mobility optimizes wear and stability in THA: opposes.

Total hip arthroplasty (THA) is an effective intervention for the treatment of arthrosis with excellent survivorship. Nonetheless, dislocation and osteolysis remain significant complications. A dual-mobility acetabular component has been advocated to improve stability and wear. Stability is imparted by increasing the effective femoral head size, which allows a larger range of motion (ROM) befor...

متن کامل

Patellofemoral arthroplasty for symptomatic nonunion after trochlear osteotomy for patellar instability: a case report

INTRODUCTION Patients with patellofemoral instability with trochlear dysplasia may be treated with trochlear osteotomy. CASE PRESENTATION We present a patient with patellofemoral instability treated with trochlear osteotomy. The procedure resulted in nonunion with painful bony impingement and isolated patellofemoral osteoarthritis. Patellofemoral arthroplasty was performed. CONCLUSION Patel...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of arthroplasty

دوره 25 4  شماره 

صفحات  -

تاریخ انتشار 2010