Neutron generator burst timing measured using a pulse shape discrimination plastic scintillator with silicon photomultiplier readout

نویسندگان

  • R M. Preston
  • J Eberhardt
  • J R. Tickner
  • Rhys M. Preston
  • John E. Eberhardt
  • James R. Tickner
چکیده

An EJ-299-34 plastic scintillator with silicon photomultiplier (SiPM) readout was used to measure the fast neutron output of a pulsed Thermo-Fisher A-325 Deuterium-Tritium sealed tube neutron generator (STNG). The SiPM signals were handled by a prototype digital pulse processing system, based on a free-running analogue to digital converter feeding a digital signal processor (DSP). Pulse shape discrimination was used to distinguish between detected fast-neutrons and gammas. Pulse detection, timing, energy and shape were all processed by the DSP in real-time.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of SiPM-Based Scintillator Tile Detectors for a Multi-Layer Fast Neutron Tracker

We present the development and characterization of thin tile scintillator detectors with silicon photomultiplier (SiPM) readout for use in a multi-layer fast-neutron tracker. The tracker is based on interleaved Timepix and plastic scintillator layers [1]. Fast-neutrons recoil protons in the plastic scintillators, which may then travel to and stop in the neighboring Timepix. Using the measured r...

متن کامل

PULSE SHAPE DISCRIMINATION CHARACTERISTICS OF STILBENE CRYSTAL, EJ-299-33 AND Li LOADED PLASTIC SCINTILLATORS FOR A HIGH RESOLUTION CODED-APERTURE NEUTRON IMAGER

Pulse shape discrimination performances of single stilbene crystal, EJ-299-33 plastic and Li loaded plastic scintillators have been compared. Pulse Gradient Analysis pulse shape discrimination algorithm has been tested for each scintillator sample, assessing their neutron/gamma separation. In this study each scintillator sample was irradiated with a Cf neutron source and, a real-time fast digit...

متن کامل

Detection Properties of a Neutron Counter Based on Scintillator, Wavelength Shifter, and Photomultiplier

A simple neutron counter based on a scintillator strip, a wavelength shifter rod, and a photomultiplier was constructed in order to compare the properties of such a detector to a commercially available He counter. A calculation of the number of photons per absorbed neutron shows that with the bright Li Gd (11BO3)3 scintillator, light levels should be sufficient to perform pulse height discrimin...

متن کامل

A Digital Method for the Discrimination of Neutrons and Rays With Organic Scintillation Detectors Using Frequency Gradient Analysis

A digital method for the discrimination of neutron and -ray events from an organic scintillator has been investigated by using frequency gradient analysis (FGA) based on the Fourier transform. Since the scintillation process and the photomultiplier tube (PMT) anode signal are often very noisy, most pulse-shape discrimination methods in a scintillation detection system (e.g., the charge comparis...

متن کامل

Efficiency of a BaF, scintillator detector for 15-150 MeV neutrons

BaF, scintillator detectors are now in common use for the measurement of y-rays over a wide energy range because of the relatively high detection efficiency and the fast response which allows subnanosecond timing [1,2]. The BaF, scintillation light consists primarily of two components with decay times of or = 600 ps and TV = 620 ns [2], and the ratio of the intensities associated with each of t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017