Comparative evaluation of Amplicor HIV-1 DNA test, version 1.5, by manual and automated DNA extraction methods using venous blood and dried blood spots for HIV-1 DNA PCR testing.
نویسندگان
چکیده
Human immunodeficiency virus (HIV) DNA polymerase chain reaction (PCR) test using venous blood sample has been used for many years in low resource settings for early infant diagnosis of HIV infection in children less than 18 months. The aim of this study was to evaluate and compare the performance characteristics of Amplicor HIV-1 DNA assay version 1.5 following processing of venous blood and dried blood spot (DBS) samples by Roche manual DNA extraction and automated Roche MagNA Pure LC instrument (MP) for HIV-1 DNA PCR testing in Dar es Salaam, Tanzania, in order to scale up early infant diagnosis of HIV infection in routine practice. Venous blood samples from children under 18 months born to HIV-infected mothers between January and April 2008 were collected. Venous blood was used to prepare cell pellet and DBS samples. DNA extractions by manual procedure and MP were performed each on cell pellet, venous blood and DBS samples and tested by Amplicor HIV-1 DNA assay. Of 325 samples included, 60 (18.5%) were confirmed HIV-infected by manual extraction performed on cell pellets. Sensitivity of the assay following MP processing of venous blood was 95% (95% CI; 86.1-99.0%) and 98.3% (95% CI; 91.1 to 99.9%) for the manual extraction and processing by MP performed on DBS samples. Specificity of the assay with all DNA extraction methods was 99.6% (95% CI; 97.9 to 100%). Performance of the assay with Roche manual extraction and processing by MP on DBS samples compared well with Roche manual extraction performed on cell pellet samples. The choice of DNA extraction method needs to be individualized based on the level of laboratory facility, volume of testing and cost benefit analysis before it is adopted for use.
منابع مشابه
Dried blood spots improve access to HIV diagnosis and care for infants in low-resource settings.
Effective health care delivery to the majority of perinatally exposed infants worldwide, including those enrolled in prevention of mother-to-child transmission programs, is hampered by lack of access to an HIV diagnosis in infancy. Dried blood spot collection from young infants for centralized HIV polymerase chain reaction (PCR) testing is attainable in low-resource settings, provided PCR metho...
متن کاملEvaluation of HIV-1 polymerase chain reaction (PCR) technique using dried blood spots (DBS) for diagnosis of perinatal transmission of HIV
Background Effective health care delivery to the majority of perinatally exposed infants is hampered by lack of access to accurate HIV diagnosis in infancy. Polymerase chain reaction is the most sensitive test to diagnose HIV-1 infection in children born to HIV seropositive mothers. The purpose of this study was to assess the feasibility and accuracy of using dried blood spot (DBS) technology i...
متن کاملEvaluation of a high-throughput diagnostic system for detection of HIV-1 in dried blood spot samples from infants in Mozambique.
We performed a comparative analysis between Roche Amplicor HIV-1 DNA test and CAPTAQ assay for the detection of HIV in 830 dried blood spot (DBS) pediatric samples collected in Mozambique. Our results demonstrated no statistical difference between these assays. The CAPTAQ assay approached nearly 100% repeatability/accuracy. The increased throughput of testing with minimal operator interference ...
متن کاملEvaluation of a single round polymerase chain reaction assay using dried blood spots for diagnosis of HIV-1 infection in infants in an African setting
BACKGROUND The aim of this study was to develop an economical 'in-house' single round polymerase chain reaction (PCR) assay using filter paper-dried blood spots (FP-DBS) for early infant HIV-1 diagnosis and to evaluate its performance in an African setting. METHODS An 'in-house' single round PCR assay that targets conserved regions in the HIV-1 polymerase (pol) gene was validated for use with...
متن کاملEvaluation of quantification of HIV-1 RNA viral load in plasma and dried blood spots by use of the semiautomated Cobas Amplicor assay and the fully automated Cobas Ampliprep/TaqMan assay, version 2.0, in Kisumu, Kenya.
In Kenya, HIV-1 viral load monitoring is commonly performed with the Cobas Amplicor using plasma specimens. Interest is growing in transitioning to real-time PCR (RT-PCR), such as the Cobas Ampliprep/Cobas TaqMan (CAP/CTM), using dried blood spots (DBS). Before implementation, direct evaluation of the two assays using DBS field specimens is required. This study compares the sensitivity, specifi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Tanzania journal of health research
دوره 12 4 شماره
صفحات -
تاریخ انتشار 2010