Contribution to red marrow absorbed dose from total body activity: a correction to the MIRD method.

نویسندگان

  • M G Stabin
  • J A Siegel
  • R B Sparks
  • K F Eckerman
  • H B Breitz
چکیده

UNLABELLED The contribution to red marrow absorbed dose from beta-emitting radionuclides distributed uniformly in the total body can be overestimated using either MIRD 11 or MIRDOSE3. The S value assigned to the red marrow target region from activity distributed in the remainder of the body is of particular concern. The assumption that the specific absorbed fraction for total body irradiating red marrow and other skeletal tissues is the inverse of the total-body mass can result in an inappropriate remainder-of-body contribution to marrow dose. We evaluated differences in the calculation of marrow dose using MIRD 11 and MIRDOSE3 formulations and developed methods to correct the results from either to remove inappropriate contributions. When bone takes up significantly less activity than is predicted from an apportionment of remainder-tissue activity based on mass, the standard remainder-of-body correction may substantially overestimate the electron component of the S value from remainder tissues to red marrow using either MIRD 11 or MIRDOSE3. If bone takes up activity, this contribution is negligible using MIRD 11 S values but remains with MIRDOSE3 S values. This overestimate can be significant, particularly when the residence time of activity in the remainder of the body is much higher than in the red marrow and a different correction is needed. As the ratio of the remainder of body to marrow residence time is lowered, the overestimate becomes less significant. CONCLUSION In this article, we show the magnitude of this overestimate (which is most important for nuclides with large "nonpenetrating" emission components and for pharmaceuticals that have a large ratio of remainder of body to marrow residence times), show the appropriate corrections to be made in each case, and propose a new method for calculating marrow dose contributions that will avoid this complication in future applications. Because all models give approximate doses for real patients, with uncertainties within those involved in these corrections, we do not suggest that changes be made to existing marrow dose estimates. We suggest only that future calculations be as accurate as possible.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of I-131, I-123 Absorbed Dose and Tc-99m in Thyroid Scanning Using MCNP Code in ORNL-MIRD Phantom

Introduction: Thyroid cancer is at the ninth from ten of common malignant cancer. A man has higher risk to get Thyroid cancer that a woman has. This organ is lain near human neck. The use of radioactive I-131, I-123 and Tc-99m for diagnosis of thyroid cancer has a risk where other organs around Thyroid will accept dose of radiation. One of the risks is large dose which is accep...

متن کامل

Determination of organ doses in radioiodine therapy using medical internal radiation dosimetry (MIRD) method

Background: Radioiodine therapy has proven to be an effective method in the treatment of patients with differentiated thyroid carcinoma after thyroidectomy. The scope of this study is to describe a method to obtain the dose of organs using medical internal radiation dosimetry (MIRD) method. At the end, the results of MIRD calculations were compared with thermoluminescent dosimeter (TLD...

متن کامل

Preliminary radiation dosimetry of a novel PET

68 Objective: In this study, we tried to estimate human absorbed dose of Ga-NODAGA-glycine as a new potential positron emission tomography (PET) renal agent based on the biodistribution data reported in healthy rats, and compare our estimation with the available absorbed dose data from technetium-99m-diethy99m lenetriaminepentaacetic acid ( Tc-DTPA). Subjects and Methods: The medical internal r...

متن کامل

MIRD dose estimate report No. 20: radiation absorbed-dose estimates for 111In- and 90Y-ibritumomab tiuxetan.

UNLABELLED Absorbed-dose calculations provide a scientific basis for evaluating the biologic effects associated with administered radiopharmaceuticals. In cancer therapy, radiation dosimetry supports treatment planning, dose-response analyses, predictions of therapy effectiveness, and completeness of patient medical records. In this study, we evaluated the organ radiation absorbed doses from in...

متن کامل

Human organ absorbed dose estimation of 166Ho-BPAMD complex based on biodistribution data of male Syrian rats

Introduction: Recently, 166Ho-BPAMD was introduced as a suitable agent for bone marrow ablation. The aim of this study was to estimate the absorbed dose of this novel agent in the human organs which is necessary before the clinical application. Methods: 166Ho was produced by direct irradiation of 165Ho in the research reactor. 250 µg...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 42 3  شماره 

صفحات  -

تاریخ انتشار 2001