“Optical Patch-clamping”

نویسندگان

  • Angelo Demuro
  • Ian Parker
چکیده

We describe an optical technique using total internal reflection fluorescence (TIRF) microscopy to obtain simultaneous and independent recordings from numerous ion channels via imaging of single-channel Ca2+ flux. Muscle nicotinic acetylcholine (ACh) receptors made up of alphabetagammadelta subunits were expressed in Xenopus oocytes, and single channel Ca2+ fluorescence transients (SCCaFTs) were imaged using a fast (500 fps) electron-multiplied c.c.d. camera with fluo-4 as the indicator. Consistent with their arising through openings of individual nicotinic channels, SCCaFTs were seen only when a nicotinic agonist was present in the bathing solution, were blocked by curare, and increased in frequency as roughly the second power of [ACh]. Their fluorescence amplitudes varied linearly with membrane potential and extrapolated to zero at about +60 mV. The rise and fall times of fluorescence were as fast as 2 ms, providing a kinetic resolution adequate to characterize channel gating kinetics; which showed mean open times of 7.9 and 15.8 ms when activated, respectively, by ACh or suberyldicholine. Simultaneous records were obtained from >400 channels in the imaging field, and we devised a novel "channel chip" representation to depict the resultant large dataset as a single image. The positions of SCCaFTs remained fixed (<100 nm displacement) over tens of seconds, indicating that the nicotinic receptor/channels are anchored in the oocyte membrane; and the spatial distribution of channels appeared random without evidence of clustering. Our results extend single-channel TIRFM imaging to ligand-gated channels that display only partial permeability to Ca2+, and demonstrate an order-of-magnitude improvement in kinetic resolution. We believe that functional single-channel imaging opens a new approach to ion channel study, having particular advantages over patch-clamp recording in that it is massively parallel, and provides high-resolution spatial information that is inaccessible by electrophysiological techniques.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated electrophysiology: high throughput of art.

Electrophysiological measurements, in particular, patch clamping, have long been regarded as the "gold standard" for assaying ion channels. Despite its high information content, the technique suffers from laborious, manual processing by highly skilled workers and extremely low throughput. Recently, a number of researchers have started to automate patch clamping by either automating conventional...

متن کامل

Chapter 1 Using microelectrodes

Microelectrodes are the basis of the techniques discussed in this book. They are used for: (1) potential recording; (2) current injection; (3) introduction into the cell of ionselective resins for measuring potential or determining the free concentration of cytosolic constituents. (1) and (2) are the procedures underlying conventional microelectrode recording, voltage-clamping and patch-clampin...

متن کامل

Microchip amplifier for in vitro, in vivo, and automated whole cell patch-clamp recording.

Patch clamping is a gold-standard electrophysiology technique that has the temporal resolution and signal-to-noise ratio capable of reporting single ion channel currents, as well as electrical activity of excitable single cells. Despite its usefulness and decades of development, the amplifiers required for patch clamping are expensive and bulky. This has limited the scalability and throughput o...

متن کامل

Optical single-channel recording: imaging Ca2+ flux through individual N-type voltage-gated channels expressed in Xenopus oocytes.

Functional studies of single membrane ion channels were made possible by the introduction of the patch-clamp technique, which allows single-channel currents to be measured with unprecedented resolution. Nevertheless, patch clamping has some limitations: including the need for physical access of the patch pipette, possible disruption of local cellular architecture, inability to monitor multiple ...

متن کامل

The Development of a High Speed 3D 2-photon Microscope for Neuroscience

The progress of neuroscience is limited by the instrumentation available to it for studying the brain. At present, there is a serious instrumentation gap between functional Magnetic Resonance Imaging (fMRI) of whole brains and the microscopic scale functional imaging possible with today’s optical microscopes and electrophysiology techniques, such as patch clamping of individual neurons. This th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of General Physiology

دوره 126  شماره 

صفحات  -

تاریخ انتشار 2005