چکیده
The benign environment and long confinement times obtained with ion storage techniques have led to some unique experiments in the area of precision measurements and fundamental constants. This is perhaps epitomized by the single electron g factor measurements at the University of Washington in which a precision of 4 parts in 10” has been attained. Now, use of lasers to cool stored ions has allowed the experimentalist to approach the goal of unperturbed atomic ions nearly at rest; most recently, spectroscopy has been performed on single “cold” trapped ions. Stored ion experiments in‘the area of precision measurements and fundamental constants will be briefly reviewed. These include experiments on e-/e+ g factors, mass spectroscopy, lifetimes, and atomic spectroscopy. The intent is to emphasize the unique environment provided by ion storage techniques for these measurements.
منابع مشابه
Ion/molecule reactions, mass spectrometry and optical spectroscopy in a linear ion trap
A linear-geometry, radio-frequency, quadrupole ion trap has been developed to generate, purify, accumulate and study atomic and molecular ions in the gas phase. By employing a trap-based system, both reactant and product ions can be stored for significant time periods, which can both enhance the efficiency of gas-phase reaction processes and create an environment to observe collision products a...
متن کاملSynthesize and Optical properties of ZnO: Eu Microspheres Based Nano-sheets at Direct and Indirect Excitation
Europium (Eu) doped ZnO microsphere based nano-sheets were synthesized through hydrothermal method. Effects of different concentrations of Europium on structural and optical properties of ZnO nano-sheets were investigated in detail. Prepared un-doped and Eu-doped ZnO samples were characterized using X-Ray diffraction (XRD), energy dispersive X-ray spectroscopy (EDX), scanning electron micro...
متن کاملComparing signal amplification of thiocyanated Gold nanoparticles in the presence of different ions
Detecting is the most important section in all kinds of sensors. In this regard, the amplification of surface plasmon resonance intensity of gold colloids nanoparticles (GNPs) was studied in the presence of several ions. GNPs were synthesized and then capped by thiocyanate and characterized via DLS and TEM image. In the next step the effect of different concentrations of ions such as iron, copp...
متن کاملMeasurement of Time Dilation by Laser Spectroscopy on Fast Stored Lithium Ions
In this work frequency measurements on fast lithium ions as a test of time dilation are presented. The measurements are carried out at the Max Planck Institute for Nuclear Physics in Heidelberg using the storage ring TSR. The transition frequency of a two-level system in the lithium ion is measured using a Doppler-free fluorescence saturation spectroscopy. The spectroscopy is realized by two co...
متن کاملPhotoelectron-photofragment coincidence spectroscopy in a cryogenically cooled linear electrostatic ion beam trap.
A cryogenically cooled linear electrostatic ion beam trap for use in photoelectron-photofragment coincidence (PPC) spectroscopy is described. Using this instrument, anions created in cold, low-duty-cycle sources can be stored for many seconds in a ~20 K environment to cool radiatively, removing energetic uncertainties due to vibrationally excited precursor anions. This apparatus maintains a wel...
متن کامل