Comparison of ESwab and Wound Fiber Swab Specimen Collection Devices for Use with Xpert SA Nasal Complete Assay
نویسندگان
چکیده
Paired nasal swab specimens were collected from patients who were undergoing routine methicillin-resistant Staphylococcus aureus (MRSA) screening prior to elective cardiac or orthopedic procedures. Each patient was swabbed using a traditional wound fiber liquid Stuart swab and an ESwab device, a flocked swab with a modified liquid Amies microbiology transport medium. The two specimens were tested using the Cepheid Xpert SA Nasal Complete assay. Results demonstrated a 95.5% agreement between the ESwab and the FDA-cleared wound fiber swab collection device.
منابع مشابه
Evaluation of Copan FecalSwab as Specimen Type for Use in Xpert C. difficile Assay
Liquid-based microbiology (LBM) devices incorporating flocked swabs and preservation medium ease transport of specimens and improve specimen yield compared to traditional fiber wound swabs; however, the performance of LBM collection devices has not been evaluated in many molecular assays. It is unclear how the differences in matrix and specimen loading with an LBM device will affect test perfor...
متن کاملClinical evaluation of the walk-away specimen processor and ESwab for recovery of Streptococcus agalactiae isolates in prenatal screening specimens.
Rectal/vaginal specimens (n = 97) were collected in parallel using ESwab and Liquid Stuart (LS) rayon fiber wrapped swab collection devices. Each collection device was used to directly inoculate culture medium and LIM broth. Medium inoculation by ESwab was conducted using the Walk-Away specimen processor (WASP). Medium inoculation by the LS device was conducted manually. The sensitivities of ES...
متن کاملComparison of the Copan ESwab system with two Amies agar swab transport systems for maintenance of microorganism viability.
Swab transport systems are used for a variety of specimen types and must maintain organism viability throughout the transport process. The Copan ESwab is a new nylon-flocked swab designed to optimize specimen collection and to minimize entrapment of the specimen. We used the quantitative elution method with recommended strains, as described in CLSI document M40-A, to evaluate the ESwab for main...
متن کاملEvaluation of the BD Max StaphSR Assay for Detecting Methicillin-Resistant Staphylococcus aureus (MRSA) and Methicillin-Susceptible S. aureus (MSSA) in ESwab-Collected Wound Samples
Staphylococcus aureus is the most common pathogen involved in skin and soft tissue infections, and it is the principal cause of surgical site infections (1–3). Most of the laboratory methods for detecting S. aureus and methicillin-resistant S. aureus (MRSA) from wounds require incubation time and do not support rapid decisions for selection of the most appropriate procedural or therapeutic inte...
متن کاملEvaluation of the BD Max MRSA XT assay for use with different swab types.
We evaluated the performance of the BD Max MRSA XT assay for use with different swab types. The 90% detection rates (95% confidence intervals) were 387 (97 to 1,551), 877 (238 to 3,230), 986 (183 to 5,287), 1,292 (328 to 5,078), 2,400 (426 to 13,518), and 5,848 (622 to 55,021) CFU/swab for Liquid Stuart, Liquid Amies, dry, Amies Gel without charcoal, ESwab collection, and Amies gel with charcoa...