Effect of framework design on fracture resistance in zirconia 4-unit all-ceramic fixed partial dentures.

نویسندگان

  • Yusuke Takuma
  • Syuntaro Nomoto
  • Toru Sato
  • Naoki Sugihara
چکیده

The purpose of this study was to conduct static load-bearing tests on 4-unit Y-TZP all-ceramic fixed partial denture (FPD) frameworks with different cross-sectional areas and forms to evaluate the influence of connector design on fracture load. Each of the central, mesial and distal connectors was prepared with one of 2 different cross-sectional areas and one of 3 different forms (one circular and two oval forms) to give a total of 18 designs. Five frameworks were then prepared for each design, making a total of 90. Each framework was cemented to the test model with glass ionomer cement. Fracture load was measured with a universal testing machine at a cross-head speed of 1.0 mm/min. A three-way ANOVA revealed significant differences in fracture load depending on cross-sectional area, central connector cross-sectional form, or mesial/distal connector cross-sectional form (p<0.01). No interaction was observed, however, between any two connector design elements. The results of a Tukey analysis revealed a significant difference between the two connector cross-sectional areas investigated, with an increase in connector cross-sectional area resulting in an increase in fracture load. Fracture load decreased as the height of the mesial or distal connector decreased. Fracture load was significantly higher in frameworks in which the height of the central connector was greater than that of the distal or mesial connector. In conclusion, these results suggest that sufficient height needs to be maintained in the mesial/distal connector to secure a high fracture load in zirconia 4-unit all-ceramic FPDs. Moreover, even when this is not possible, a high fracture load may still be obtained by making the height of the central connector as great as possible. Furthermore, extending the connector cross-sectional area is effective in increasing fracture load.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Pontic Framework Design on the Fracture Resistance of Implant-supported All-ceramic Fixed Partial Dentures

OBJECTIVE The purpose of this study was to compare the fracture resistance of implant-supported all-ceramic fixed partial dentures, which have three different pontic designs. MATERIAL AND METHODS Two implants were placed in a metal model simulating mandibular left second premolar and mandibular left second molar. Thirty standardized 3-unit all-ceramic fixed partial dentures with biconvex, con...

متن کامل

Fracture force of tooth-tooth- and implant-tooth-supported all-ceramic fixed partial dentures using titanium vs. customised zirconia implant abutments.

OBJECTIVES Tooth-coloured customised implant abutments and full ceramic supraconstructions thereon can be made of zirconia by computer-aided manufacturing (CAM). The aim of this study was to examine the potential limits of zirconia three-unit fixed partial dentures made on customised zirconia implant abutments in implant-tooth supported cases. MATERIAL AND METHODS Rigidly mounted implants (Xi...

متن کامل

Load-bearing capacity of all-ceramic three-unit fixed partial dentures with different computer-aided design (CAD)/computer-aided manufacturing (CAM) fabricated framework materials.

The purpose of this in vitro study was to compare the load-bearing capacity of posterior three-unit fixed dental prostheses (FDP) produced with three different all-ceramic framework materials: glass-infiltrated alumina (ICA), glass-infiltrated alumina strengthened with zirconia (ICZ), and yttria-stabilized polycrystalline zirconia (YZ). Additionally, the influence on aging of mechanical cyclic ...

متن کامل

Fracture Strength of Three-Unit Implant Supported Fixed Partial Dentures with Excessive Crown Height Fabricated from Different Materials

OBJECTIVES Fracture strength is an important factor influencing the clinical long-term success of implant-supported prostheses especially in high stress situations like excessive crown height space (CHS). The purpose of this study was to compare the fracture strength of implant-supported fixed partial dentures (FPDs) with excessive crown height, fabricated from three different materials. MATE...

متن کامل

Effect of connector design on fracture resistance of zirconia all-ceramic fixed partial dentures.

The purpose of the present study was to determine the relationship between cross-sectional design and fracture load using a static load bearing test in yttria-stabilized tetragonal zirconia polycrystal ceramic frameworks on a molar fixed partial denture. The test framework was designed as a 3-unit bridge with two abutment teeth at the second premolar and second molar of the mandible. The cross-...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Bulletin of Tokyo Dental College

دوره 54 3  شماره 

صفحات  -

تاریخ انتشار 2013