A novel electrode–pipette design for simultaneous recording of extracellular spikes and iontophoretic drug application in awake behaving monkeys
نویسندگان
چکیده
We developed a novel design of an electrode-pipette combination (EPC) which allows access to brain structures in awake behaving primates without the need for guide tubes or to mechanically open the dura prior to electrode insertion. The EPC consists of an etched tungsten in glass electrode flanked by two pipettes which allow for local and highly controlled iontophoretic administration of neuroactive substances. These EPCs have excellent single cell isolation properties and are sturdy enough to penetrate the primate dura for up to 8 weeks following either a craniotomy or a dura scrape (i.e. even after substantial built up of fibrous scar tissue). We show that the EPCs can be used to selectively manipulate the cholinergic system in primate V1 during passive fixation and while animals perform an attentionally demanding task.
منابع مشابه
Simultaneous multi-site recordings and iontophoretic drug and dye applications along the trigeminal system of anesthetized rats.
A multi-electrode system that permits simultaneous recordings from multiple neurons and iontophoretic applications at two or three different brain sites during acute experiments is described. This system consists of two or three microdrive terminals, each of which includes four electrodes that can be moved independently and used for both extracellular recordings and microiontophoretic drug admi...
متن کاملA screw microdrive for adjustable chronic unit recording in monkeys.
A screw microdrive is described that attaches to the grid system used for recording single neurons from brains of awake behaving monkeys. Multiple screwdrives can be mounted on a grid over a single cranial opening. This method allows many electrodes to be implanted chronically in the brain and adjusted as needed to maintain isolation. rights reserved.
متن کاملinnovative methodology Problem of Dural Scarring in Recording From Awake, Behaving Monkeys: A Solution Using 5-Fluorouracil
Spinks, R. L., S. N. Baker, A. Jackson, P. T. Khaw, and R. N. Lemon. Problem of dural scarring in recording from awake, behaving monkeys: a solution using 5-fluorouracil. J Neurophysiol 90: 1324–1332, 2003; 10.1152/jn.00169.2003. In studies using single neuron recordings from awake, behaving monkeys, it is necessary to make repeated transdural penetrations using fragile microelectrodes. The tou...
متن کاملA non-invasive head-holding device for chronic neural recordings in awake behaving monkeys.
BACKGROUND We have developed a novel head-holding device for behaving non-human primates that affords stability suitable for reliable chronic electrophysiological recording experiments. The device is completely non-invasive, and thus avoids the risk of infection and other complications that can occur with the use of conventional, surgically implanted head-fixation devices. NEW METHOD The devi...
متن کاملReal-Time Dopamine Measurement in Awake Monkeys
Fast-scan cyclic voltammetry (FSCV) is often used to measure real-time dopamine (DA) concentrations in awake, behaving rodents. Extending this technique to work in monkeys would provide a platform for advanced behavioral studies and a primate model for preclinical research. The present study demonstrates the feasibility of DA recordings in two awake monkeys (Macaca mulatta) using a mixture of t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 158 شماره
صفحات -