Absolute Air-kerma Measurement in a Synchrotron Radiation Beam by Ionization Free-air Chamber
نویسنده
چکیده
A dosimetric procedure to assure the traceability to the air-kerma standard of the measurements performed in synchrotron radiation beams, was implemented at the “Istituto Nazionale di Metrologia delle Radiazioni Ionizzanti” of ENEA (INMRI-ENEA). To this purpose, absolute air-kerma measurements by the ENEA standard free-air chamber for low energy x-rays have been performed at the SYRMEP (SYnchrotron Radiation for Medical Physics) beamline of the ELETTRA light source in Trieste (Italy) where a program of clinical mammography based on phase contrast imaging has been developed in the framework of the SYRMA project (SYnchrotron Radiation for MAmmography). The synchrotron radiation beams to be characterized were monochromatic x-rays with energy in the range from 8 keV to 35 keV and the reference point for measurements corresponded to the centre of the breast when the patient lies on her support. The absolute air-kerma measurements were also used to calibrate two monitor chambers and an ionization free-air chamber specially designed and realized by ENEA to act as transfer standard in the synchrotron radiation beams. The irradiation conditions for measurements – both beam quality and geometry – were very different from the reference conditions at the INMRI-ENEA. According to the actual conditions, the diaphragm of the ENEA standard chamber was modified and some correction factors were re-determined by Monte Carlo calculations based on the PENELOPE code or by experimental measurements. In particular, the mass air attenuation coefficients of these monochromatic x-rays were experimentally determined to obtain the correction for photon attenuation in air.
منابع مشابه
Conception and realization of a parallel-plate free-air ionization chamber for the absolute dosimetry of an ultrasoft X-ray beam.
We report the design of a millimeter-sized parallel plate free-air ionization chamber (IC) aimed at determining the absolute air kerma rate of an ultra-soft X-ray beam (E = 1.5 keV). The size of the IC was determined so that the measurement volume satisfies the condition of charged-particle equilibrium. The correction factors necessary to properly measure the absolute kerma using the IC have be...
متن کاملStandard calibration of ionization chambers used in radiation therapy dosimetry and evaluation of uncertainties
Background: Absolute dosimetry of external beam radiotherapy is carried out by the use of ionization chambers. These chambers must be calibrated at a standard dosimetry laboratory before any use in clinical dosimetry. The secondary standard dosimetry laboratory of Iran (SSDL) has the duty of calibrating the ionization chambers used in radiotherapy centers in Iran. Materials and Methods...
متن کاملFabrication of Free Air Well Type Ionization Chamber and Calculational Assessment and Measurement of Its Operational Characteristics
Introduction: Well type ionization chamber is a measuring device which is used to determine the activity of brachytherapy sources. The chamber has a cylindrical volume in which a cylindrical tube is mounted in the middle of the chamber. For the measurements, the brachytherapy sources are transferred to the middle of the tube. Materials and Methods: For designing the well type chamber, the measu...
متن کاملPlane-parallel ionization chamber for X-radiation of conventional radiography and mammography* Câmara de ionização de placas paralelas para radiação-X de radiografia convencional e mamografia
OBJECTIVE: To develop a double-faced plane-parallel ionization chamber for measurement of air kerma and air kerma rate in X-radiation fields utilized in conventional radiography and mammography. MATERIALS AND METHODS: The chamber has entrance windows made of aluminized polyester film, inner and guard electrodes of aluminum at one side (face A) and graphite at the other side (face G). The presen...
متن کاملCalibration of iridium-192 source by ionization chamber for high dose rate brachytherapy
Background: The effectiveness and safety of brachytherapy treatment is mainly concerned with the calibration of sources and their traceability to internationally accepted Standards. Secondary Standard Dosimetry Laboratory (SSDL) does not offer calibration of ionization chambers with gamma-ray spectrum of high dose rate source 192Ir . This work has been carried out to calibrate the high dose rat...