Color Doppler imaging of orbital arteries for detection of carotid occlusive disease.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Distal to a hemodynamically significant stenosis, the Doppler effect becomes dampened. Thus, measuring the flow profile in the ophthalmic artery and the central retinal artery with color Doppler imaging may provide hemodynamic information about the carotid circulation. METHODS To validate the flow profile measurement with color Doppler imaging in the ophthalmic and central retinal arteries and to determine the sensitivity and specificity of this examination in the detection of hemodynamically significant carotid stenosis, we compared color Doppler imaging examinations with ocular pneumoplethysmography and ophthalmodynamometry examinations in 66 patients with atherothrombotic ischemic cerebrovascular disease. The degree of carotid stenosis in these patients was determined by a duplex scan with color Doppler imaging, and 57 patients underwent angiography to verify the stenosis. RESULTS The flow velocities (systolic peak velocity and end-diastolic velocity) and pulsatility indices (A/B ratio and resistance index) in the ophthalmic and central retinal arteries decreased as the degree of carotid stenosis increased. There is a statistically significant difference in the mean of systolic peak velocity and the mean of end-diastolic velocity of the ophthalmic and central retinal arteries among groups with various degrees of carotid stenosis (P < .02). Using the flow velocities of the ophthalmic and central retinal arteries to diagnose carotid stenosis (> or = 75% stenosis and occlusion), 8 cm/s for systolic peak velocity in the central retinal artery and 29 cm/s for systolic peak velocity plus flow direction reversal in the ophthalmic artery gave the maximum accuracy (sensitivities, 84% and 85.7% and specificities, 89.6% and 81.7%, respectively). The systolic peak velocity in the central retinal artery varied directly with the systolic pressure of the ophthalmic and central retinal arteries. CONCLUSIONS The flow velocity and pulsatility in orbital arteries examined by color Doppler imaging provide further hemodynamic information; this test can be used to complement current sonographic examination of carotid disease.
منابع مشابه
بررسی دقت و همبستگی سونوگرافی داپلر رنگی با آنژیوگرافی در تعیین شدت تنگی عروق کاروتید گردنی در بیماران ایسکمی مغزی
This is retrospective double-blind research, which was carried out in Imam Khomeini hospital in order to study the accuracy of color Doppler ultrasonography for detecting the site and grade of stenosis in cervical carotid artery. 40 patients with mean age of 62 years studied with color Doppler before DSA angiography. The most common sites of stenosis were left internal carotid (39.5%) and right...
متن کاملDetection of carotid artery stenosis by in vivo duplex ultrasound: correlation with planimetric measurements of the corresponding postmortem specimens.
BACKGROUND AND PURPOSE The correct detection and quantification of carotid artery disease are of decisive impact on patient prognosis and adequate treatment. In this study, we evaluated the ability of ultrasonography to detect and to grade carotid artery stenosis through a comparison of the in vivo ultrasound findings with the planimetric analysis of the corresponding postmortem specimens. ME...
متن کاملCarotid artery disease assessed by color Doppler flow imaging: correlation with standard Doppler sonography and angiography.
Carotid artery disease was assessed in 180 patients by means of color Doppler flow imaging. Color Doppler findings in 360 carotid arteries were compared with the results of standard Doppler sonography, and color Doppler findings in 60 bifurcations were compared with the results of intraarterial angiography. The sensitivity of color Doppler for the detection of carotid disease was 100% when comp...
متن کاملColor velocity imaging quantification in the detection of intracranial collateral flow.
BACKGROUND AND PURPOSE The development of intracranial collateral circulation is associated with a lower risk of stroke. A noninvasive technique that can reliably detect the presence of intracranial collaterals would be a valuable factor in the assessment of risk in patients with occlusive cerebrovascular disease. METHODS Color velocity imaging quantification was used to measure the blood flo...
متن کاملSpontaneous dissection of the carotid and vertebral arteries.
The carotid color Doppler ultrasound is usually the first imaging modality employed for the assessment of patients with cerebrovascular symptoms. The recognition of the distal stenoocclusive flow pattern is key for the detection of spontaneous dissection of the internal carotid and vertebral arteries in young patients who present cerebral ischaemic signs. We present six cases of patients whose ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Stroke
دوره 24 8 شماره
صفحات -
تاریخ انتشار 1993