Accuracy and precision of a novel non-invasive core thermometer.

نویسندگان

  • O Kimberger
  • R Thell
  • M Schuh
  • J Koch
  • D I Sessler
  • A Kurz
چکیده

BACKGROUND Accurate measurement of core temperature is a standard component of perioperative and intensive care patient management. However, core temperature measurements are difficult to obtain in awake patients. A new non-invasive thermometer has been developed, combining two sensors separated by a known thermal resistance ('double-sensor' thermometer). We thus evaluated the accuracy of the double-sensor thermometer compared with a distal oesophageal thermometer to determine if the double-sensor thermometer is a suitable substitute. METHODS In perioperative and intensive care patient populations (n=68 total), double-sensor measurements were compared with measurements from a distal oesophageal thermometer using Bland-Altman analysis and Lin's concordance correlation coefficient (CCC). RESULTS Overall, 1287 measurement pairs were obtained at 5 min intervals. Ninety-eight per cent of all double-sensor values were within +/-0.5 degrees C of oesophageal temperature. The mean bias between the methods was -0.08 degrees C; the limits of agreement were -0.66 degrees C to 0.50 degrees C. Sensitivity and specificity for detection of fever were 0.86 and 0.97, respectively. Sensitivity and specificity for detection of hypothermia were 0.77 and 0.93, respectively. Lin's CCC was 0.93. CONCLUSIONS The new double-sensor thermometer is sufficiently accurate to be considered an alternative to distal oesophageal core temperature measurement, and may be particularly useful in patients undergoing regional anaesthesia.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An evaluation of deep-forehead temperature (spoton®) in ICU patients after cardiac surgery

Introduction Core temperature is important for the safety of patients in ICU. Although blood temperature (Tbl) has been accepted as the gold standard for core temperature monitoring, it requires an invasive procedure. A recently developed new thermometer, SpotOn(3M, St. Paul, MN) that measures deep-forehead temperature (Tdf) can measure core temperature during surgery1) in a noninvasive manner....

متن کامل

A Novel Study on Non-invasive Assessment of Renal Osteodystrophy among Iranian Hemodialysis Patients

Background: Renal osteodystrophy (ROD) is a common bone and mineral metabolism disorder in patients with end-stage renal disease (ESRD). This study aimed to determinate the frequency of the subtypes of ROD and evaluate the diagnostic value of biochemical as the well as radiographic markers for the diagnosis of ROD among hemodialysis patients in Golestan province of Iran.  Materials and Methods...

متن کامل

SYSTEMATIC REVIEW PROTOCOL The use of non-invasive therm ometers in healthcare facilities: a scoping review protocol

© Review objective and questions: The objective of the review is to map the available evidence to provide an overview of the use of non-invasive thermometers in the general context of health care. The specific questions, in regards to the available international published and unpublished literature, are: What types of non-invasive thermometers have been used? What manufacturers/brand of thermom...

متن کامل

Propensity based classification: Dehalogenase and non-dehalogenase enzymes

The present work was designed to classify and differentiate between the dehalogenase enzyme to non–dehalogenases (other hydrolases) by taking the amino acid propensity at the core, surface and both the parts. The data sets were made on an individual basis by selecting the 3D structures of protein available in the PDB (Protein Data Bank). The prediction of the core amino acid were predicted by I...

متن کامل

Non-invasive measurement of brain temperature with microwave radiometry: demonstration in a head phantom and clinical case.

This study characterizes the sensitivity and accuracy of a non-invasive microwave radiometric thermometer intended for monitoring body core temperature directly in brain to assist rapid recovery from hypothermia such as occurs during surgical procedures. To study this approach, a human head model was constructed with separate brain and scalp regions consisting of tissue equivalent liquids circu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 103 2  شماره 

صفحات  -

تاریخ انتشار 2009