Spectral responsivity uncertainty of silicon photodiodes due to calibration spectral bandwidth
نویسندگان
چکیده
A systematic study on the uncertainty in spectral responsivity of silicon photodiodes due to the calibration spectral bandwidth is presented. Two of the most common types of silicon photodiodes in the field of optical power measurements have been used in this work: one with thickness of about 100 nm of SiO2 and the other with thickness about 27 nm of SiO2. It is shown that the spectral responsivity error will be negligible ( 5 × 10−4) using a spectral bandwidth up to 20 nm in the calibration if the effective wavelength of the spectral transfer function, including the distribution of the radiation source, is calculated and the measured responsivity is assigned to that effective wavelength. In other cases, the error depends not only on the extent of the interval isolated by the spectral analysis system but also on the shape of the spectral isolation function.
منابع مشابه
Bilateral NIST-PTB Comparison of Spectral Responsivity in the VUV
To compare the calibration capabilities for the spectral responsivity in the vacuum-ultraviolet spectral region between 135 nm and 250 nm, PTB and NIST agreed on a bilateral comparison. Calibrations of semiconductor photodiodes as transfer detectors were performed using monochromatized synchrotron radiation and cryogenic electrical substitution radiometers as primary detector standards. Great i...
متن کاملImproved Near-Infrared Spectral Responsivity Scale
A cryogenic radiometer-based system was constructed at the National Institute of Standards and Technology for absolute radiometric measurements to improve detector spectral power responsivity scales in the wavelength range from 900 nm to 1800 nm. In addition to the liquid-helium-cooled cryogenic radiometer, the system consists of a 100 W quartz-tungsten-halogen lamp light source and a 1 m singl...
متن کاملWidely Tunable Twin-Beam Light Source based on Quasi-Phase-Matched Optical Parametric Generator as a Spectral Responsivity Comparator between InGaAs and Si Photodiodes
We present a twin-beam light source based on quasi-phase-matched (QPM) continuous-wave (CW) optical parametric generator (OPG). The source emits collinearly the signal and the idler beams at a power level of 1 nW in wavelength ranges from 790 nm to 920 nm and from 1260 nm to 1620 nm, respectively, with a bandwidth of less than 2 nm. The quantum correlation in the OPG process can be used to dire...
متن کاملNEWRAD 2005: Characterization of detectors for extreme UV radiation
Photodiodes are used as easy-to-operate detectors in the extreme ultraviolet (EUV) spectral range. The Physikalisch-Technische Bundesanstalt calibrates photodiodes in the spectral range from 1 nm to 30 nm with an uncertainty of the spectral responsivity of 0.3% or better. For the dissemination of these high-accuracy calibrations, we investigated the stability and linearity of silicon n-on-p jun...
متن کاملThe Detector-Based Candela Scale and Related Photometric Calibration Procedures at NIST
The candela, one of the SI base units, has been realized by using absolutely calibrated detectors rather than sources. A group of eight photometers was constructed using silicon photodiodes, precision apertures, and glass filters for V (λ) match. Their absolute spectral responsivities were calibrated against the NIST absolute spectral responsivity scale. The measurement chain has been significa...
متن کامل