Response characteristics of esophageal balloon catheters handmade using latex and nonlatex materials

نویسندگان

  • Troy J Cross
  • Sophie Lalande
  • Robert E Hyatt
  • Bruce D Johnson
چکیده

The measurement of esophageal pressure allows for the calculation of several important and clinically useful parameters of respiratory mechanics. Esophageal pressure is often measured with balloon-tipped catheters. These catheters may be handmade from natural latex condoms and polyethylene tubing. Given the potential of natural latex to cause allergic reaction, it is important to determine whether esophageal catheter balloons can be fabricated, by hand, using nonlatex condoms as construction materials. To determine the static and dynamic response characteristics of esophageal balloon catheters handmade from latex and nonlatex materials, six esophageal catheter balloons were constructed from each of the following condom materials: natural latex, synthetic polyisoprene, and polyurethane (18 total). Static compliance and working volume range of each balloon catheter was obtained from their pressure-volume characteristics in water. The dynamic response of balloon catheters were measured via a pressure "step" test, from which a third-order underdamped transfer function was modeled. The dynamic ranges of balloon catheters were characterized by the frequencies corresponding to ±5% amplitude- and phase-distortion (fA5% and fφ5%). Balloon catheters handmade from polyurethane condoms displayed the smallest working volume range and lowest static balloon compliance. Despite this lower compliance, fA 5% and fφ5% were remarkably similar between all balloon materials. Our findings suggest that polyisoprene condoms are an ideal nonlatex construction material to use when fabricating esophageal catheter balloons by hand.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the efficacy of a nonlatex condom: results from a randomized, controlled clinical trial.

CONTEXT To reduce unintended pregnancy and HIV infection, it is critical to develop reliable male condoms that will attract consumers who reject conventional latex condoms. METHODS In a prospective clinical trial conducted in 1998-2000, 830 monogamous couples were randomized in equal numbers to use either a nonlatex condom or a commercial natural latex condom for six months as their only meth...

متن کامل

The final steps in converting a health care organization to a latex-safe environment.

BACKGROUND In a follow-up to a previous article, which described the approach at The Johns Hopkins Medical Institutions to establishing a latex-safe environment, subsequent efforts to convert all the sterile gloves to nonlatex products and thereby complete the implementation of a latex-safe program are reported. Before the complete conversion to nonlatex sterile gloves, operating room use had i...

متن کامل

Successful Use of Biliary Duct Balloon Dilator in Repairing Post-Surgical Esophageal Stricture in premature infant

Congenital esophageal atresia needs to be surgically corrected as soon as possible. Some will present with post surgical stricture that needs to be dilated by a balloon dilator. This procedure is difficult in premature born due to infant esophageal size and availability of equipments. We herby report the first case in a premature infant with post surgical esophageal stricture of esophageal atre...

متن کامل

Assessing respiratory function depends on mechanical characteristics of balloon catheters.

BACKGROUND Respiratory muscle function and lung and chest wall mechanics are reliably assessed by esophageal and gastric balloon catheters. The aim of this in vitro bench study was to assess the mechanical properties of commercially available balloon catheters using an experimental model with 3 defined compliances (27, 54, 90 mL/cm H2O). METHODS Six catheters were investigated in 4 conditions...

متن کامل

Latex anaphylaxis caused by a Swan-Ganz catheter.

A 78-year-old woman visited the division of cardiovascular disease in our hospital. She underwent a cardiac catheter examination, and a Swan-Ganz catheter was inserted. Several minutes later, she developed anaphylactic shock. She had no past history of latex allergy, but did have a banana allergy. Skin prick tests showed a positive reaction to an extract of latex gloves and an extract of the ba...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2015