Image quality and attenuation values of multi detector CT coronary angiography using high iodine-concentration contrast material: A comparison of the use of iopromide 370 and iomeprol 400

نویسندگان

  • Eun Young Kim
  • Dae Wook Yeh
  • Yeon Hyeon Choe
  • Won Jae Lee
  • Hyo Keun Lim
چکیده

BACKGROUND Effects of high iodine-concentration contrast material on the image quality of coronary CT angiography (CCTA) have not been well evaluated. PURPOSE To compare the image quality and attenuation values of CCTA between patients administered iopromide 370 and iomeprol 400 with the use of 64-slice multidetector CT. MATERIAL AND METHODS Patients were prospectively enrolled and were randomized into two groups (group A, 151 patients received iopromide 370, iodine flux = 1.48 g I/s; group B, 146 patients received iomeprol 400, iodine flux = 1.60 g I/s). CT attenuation was measured in the coronary arteries and great arteries and measurements were standardized based on an iodine flux of 1.50 g I/s. The image quality of 15 coronary artery segments was graded by two radiologists in consensus with the use of a four-point scale (1 = excellent to 4 = poor enhancement). Non-parametric statistical approaches were used to compare the two groups. RESULTS The median attenuation values in the coronary arteries were 454 HU and 464 HU for iopromide 370 and iomeprol 400, respectively, and they did not differ (P = 0.26). When standardizing for an iodine flux, significantly higher attenuation values were found for iopromide 370 (median = 460 HU, range = 216–791 HU) compared with iomeprol 400 (median = 435 HU, range = 195–758 HU) (P = 0.006). The median image quality score of coronary arterial segments was 1 (range 1–2) for both groups (P = 0.84). CONCLUSION The attenuation values in the coronary arteries after injection of the same amount of two high iodine-concentration contrast materials at the same flow rate with different iodine fluxes are similar with no difference in image quality. With standardization for an iodine flux, the attenuation is significantly higher when using iopromide 370.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of X-ray permeability of surgical gloves coated with different contrast agents

OBJECTIVE We aimed to investigate the effectiveness and radiation protection capability of latex gloves coated with various contrast agents as an alternative to lead gloves. METHODS The following six groups were created to evaluate the permeability of X-ray in this experimental study: lead gloves, two different non-ionic contrast media (iopromide 370/100 mg I/mL and iomeprol 400/100 mg I/mL),...

متن کامل

Low kilovolt “prospective ECG-triggering” vs. “retrospective ECG-gating” coronary CTA: comparison of image quality and radiation dose

Background: To compare image quality and radiation doses of low kilovolt (kV) “prospective ECG-triggering” (PT) and standard “retrospective ECG-gating” (RG) coronary computed tomography (CT) angiography. Materials and Methods: A total of 101 consecutive patients (76 males, 25 females; mean age: 55.44 ± 8.28 years) with low-to-intermediate risk status for coronary artery disease and with a body ...

متن کامل

Prospective-triggered high-pitch spiral versus sequential dual-source CT coronary angiography: comparison of image quality and radiation dose

Background: Prospectively electrocardiography (ECG)-triggered high-pitch spiral coronary computed tomography angiography (CCTA) is a unique scan mode for dual-source CT (DSCT). Our reports aim to compare image quality and radiation dose of CCTA using high-pitch spiral or sequential acquisition mode in patients with low and stable heart rates. Materials and Methods: Patients with low and stable ...

متن کامل

Low-Dose Scanning Technology Combined with Low-Concentration Contrast Material in Renal Computed Tomography Angiography (CTA): A Preliminary Study

BACKGROUND This study is to investigate the feasibility of low iodine concentration contrast material (CM) combined with low tube voltage and adaptive statistical iterative reconstruction (ASIR) in renal computed tomography angiography (CTA). MATERIAL AND METHODS A total of 136 patients were enrolled in this prospective trial, and randomly divided into two groups: group A (n=68) and group B (n=...

متن کامل

The effect of contrast agent on delivered dose during diagnostic imaging of thoracic region

This study evaluated the impact of contrast material on the estimation of absorbed dose due to computed tomography pulmonary angiography (CTPA) using the ICRP reference phantoms. To address this issue, we modified the previously developed physiologically based pharmacokinetic (PBPK) model to be conformed to the ICRP reference phantoms. Regarding the standard contrast material injection protocol...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 51  شماره 

صفحات  -

تاریخ انتشار 2010