Tuboimpedance: A New Test of Eustachian Tube Function.

نویسندگان

  • Matthew E Smith
  • Charlie C Zou
  • Andrew J C Blythe
  • James R Tysome
چکیده

Objective Eustachian tube (ET) dysfunction is most frequently caused by a failure of the ET to adequately open; however, there is currently no reliable method of assessing this. Tubomanometry has recently shown good interindividual repeatability as a measure of ET function by measuring middle ear pressure after the application of regulated nasopharyngeal pressures during swallowing. We present the first reports of a novel test: middle ear impedance measurements during standard nasopharyngeal pressure application (tuboimpedance). We assess repeatability in healthy ears and any advantages over tubomanometry. Study Design Exploratory cohort diagnosis study. Setting Tertiary referral center. Subjects Twenty screened, healthy ears (10 volunteers). Methods Tubomanometry and tuboimpedance tests were performed while individuals swallowed with applied nasopharyngeal pressures of 20, 30, 40, and 50 mbar. Eustachian tube opening detection rate and test repeatability (measured by intraclass correlation coefficient [ICC]) for immediate and delayed repeats at each pressure were compared. Results ET opening was detected more frequently using tuboimpedance, with a 100% detection rate using a nasopharyngeal pressure of 30 mbar or more, compared to 88% to 96% with tubomanometry. Detection of ET opening at 20 mbar was possible with tuboimpedance. Repeatability of both tests was mostly strong (ICC >0.7) for both immediate and delayed repeats. Repeatability for the tubomanometry R value was only fair to moderate. Conclusion Tuboimpedance may provide a repeatable measure of ET opening that is easier to perform due to lower nasopharyngeal pressures required and fewer issues with poor ear-probe sealing. Further assessment in patients with different forms of ET dysfunction is required.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

PREVALENCE OF TRAUMATIC TYMPANIC MEMBRANE PERFORATION IN PATIENTS WITH A PATULOUS EUSTACHIAN TUBE

Background: With respect to physical relations in force and pressure, we hypothesized that the prevalence of traumatic tympanic membrane perforation in patients with a patulous Eustachian tube is greater than normal, because in Eustachian tube patency, the internal air pressure of the middle ear will not increase after compression, subsequent to trauma. Therefore the force upon the tympanic...

متن کامل

بررسی اثرات عملکرد شیپور استاش بر روی سلامت پیوند پرده صماخ در اعمال جراحی تمپانوپلاستی و ماستوئیدکتومی-تمپانوپلاستی به علت عفونت مزمن گوش میانی

Chronic otitis media is a common disease which can lead to serious complications or even death. Betterment of eustachian tube function is effective on results of operations. The main goal of this study was to determine the effect of eustachian tube function on outcome of graft in tympanoplasty or tympanomastoidectomy for chronic otitis media. We prospectively studied 126 patients who underwent ...

متن کامل

Eustachian tube dysfunction in OSMF- often present seldom discovered

OBJECTIVES To evaluate the effect of OSMF on the eustachian tube function and to correlate it with various grades of the disease. STUDY DESIGN Twenty OSMF patients (40 ears) and 20 healthy controls (40 ears) were evaluated for eustachian tube function by eustachian tube function test, tympanometry and audiometry. RESULTS The audiometric and tympanometric analysis showed no significant diffe...

متن کامل

Role of Impedance Audiometry in Evaluation of Eustachian Tube Function and Its Correlation with Tympanoplasty Surgery Outcome: Our Experience

Background: Normal Eustachian tube function is one of the important factor required for successful tympanoplasty outcome. A clinically useful test for assessment of Eustachian tube function is still lacking. Aims And Objectives: To evaluate Eustachian tube function by impedance audiometry and compare the outcome of surgery with respect to graft take up in normal and abnormal Eustachian tube fun...

متن کامل

بررسی رابطه رینیت آلرژیک با کاهش شنوایی(یک مطالعه 5 ساله بر روی 800 بیمار)

Background : Allergic rhinitis is among the most common respiratory disorders that has been increased during the recent decades due to air pollution. Most of prior studies have investigated the association between allergic rhinitis and hearing loss among children, however, scanty reports address the issue among adults, thus the present study was conducted among patients referring to a universit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery

دوره 156 4  شماره 

صفحات  -

تاریخ انتشار 2017