Outcomes and complications associated with off-label and untested use of drug-eluting stents.
نویسندگان
چکیده
CONTEXT Limited data exist regarding use of drug-eluting stents outside of approved indications in real-world settings. OBJECTIVES To determine the frequency, safety, and effectiveness of drug-eluting stents for off-label (restenosis, bypass graft lesion, long lesions, vessel size outside of information for use recommendation) and untested (left main, ostial, bifurcation, or total occlusion lesions) indications in percutaneous coronary intervention (PCI). DESIGN, SETTING, AND PATIENTS Observational, prospective, multicenter registry to evaluate in-hospital, 30-day, and 1-year outcomes among patients undergoing PCI between January and June 2005 in 140 US academic and community medical centers. Of 7752 PCI-treated patients, 6993 (90%) received drug-eluting stents; of these, 5851 (84%) received no other devices. Standard, off-label, and untested use was determined in 5541 (95%) of these 5851 patients, constituting the study cohort. MAIN OUTCOME MEASURES Frequency of off-label and untested use, 1-year repeat target vessel revascularization, and composite of death, myocardial infarction (MI), or stent thrombosis at in-hospital follow-up and during 1 year of follow-up. RESULTS Of 5541 patients receiving drug-eluting stents, 2588 (47%) received stents for off-label or untested indications. Adjusted in-hospital risk of death, MI, or stent thrombosis was not statistically different with off-label or untested vs standard use. At 30 days, the risk of this composite end point was significantly higher with off-label use (adjusted hazard ratio [HR], 2.08; 95% confidence interval [CI], 1.24-3.48; P = .005) but not untested use (adjusted HR, 1.45; 95% CI, 0.79-2.67; P = .23). Excluding early events, this end point was not different at 1 year with off-label use (adjusted HR, 1.10; 95% CI, 0.79-1.54; P = .57) or untested use (adjusted HR, 0.91; 95% CI, 0.60-1.38; P = .66). At 1 year, compared with standard use, significantly higher rates of target vessel revascularization were associated with off-label use (adjusted HR, 1.49; 95% CI, 1.13-1.98; P = .005) and untested use (adjusted HR, 1.49; 95% CI, 1.10-2.02; P = .01), although absolute rates were low (standard, 4.4% [n = 113]; off-label, 7.6% [n = 95]; untested, 6.7% [n = 72]). CONCLUSIONS In contemporary US practice, off-label and untested use of drug-eluting stents is common. Compared with standard use, relative early safety is lower with off-label use, and the long-term effectiveness is lower with both off-label and untested use. However, the absolute event rates remain low.
منابع مشابه
Immunosuppressive therapy and tolerance of organ allografts.
Moses JW, Leon MB, Popma JJ, et al. Sirolimus-eluting stents versus standard stents in patients with stenosis in a native coronary artery. N Engl J Med 2003;349:1315-23. Stone GW, Ellis SG, Cox DA, et al. A polymer-based, paclitaxel-eluting stent in patients with coronary artery disease. N Engl J Med 2004;350:221-31. Pfisterer M, Brunner-La Rocca HP, Buser PT, et al. Late clinical events after ...
متن کاملOutcomes and complications with off-label use of drug-eluting stents: results from the STENT (Strategic Transcatheter Evaluation of New Therapies) group.
OBJECTIVES This study evaluates outcomes and complications in patients treated with drug-eluting stents (DES) for "off-label" indications. BACKGROUND Drug-eluting stents have been effective in randomized trials, but their safety and efficacy for off-label indications has not been well studied. METHODS The STENT (Strategic Transcatheter Evaluation of New Therapies) Registry is the largest mu...
متن کاملA comparison of bare-metal and drug-eluting stents for off-label indications.
BACKGROUND Recent reports suggest that off-label use of drug-eluting stents is associated with an increased incidence of adverse events. Whether the use of bare-metal stents would yield different results is unknown. METHODS We analyzed data from 6551 patients in the National Heart, Lung, and Blood Institute Dynamic Registry according to whether they were treated with drug-eluting stents or ba...
متن کاملOff-label use and the spectre of drug-eluting stent thrombosis.
Off-label use of drug-eluting stents (DES) occurs when the implantation takes place outside the scope of the approved label. In the case of DES, the “on-label” indications are limited to short de novo lesions in coronary arteries measuring 2.5 to 3.75 mm in diameter. As anticipated, the use of paclitaxel-eluting stents (PES) has shown excellent outcomes with low rates of target lesion revascula...
متن کاملSafety and effectiveness of drug-eluting stents in Chinese patients with coronary artery disease with off- and on-label indications: results from a single-centre registry
BACKGROUND Off-label use of drug-eluting stents (DES) is more common than on-label use and may be associated with a persistently higher rate of adverse angiographic and clinical outcomes. OBJECTIVE To evaluate the safety and effectiveness of unrestricted use of DES in everyday practice in a Chinese population. METHODS Between January 2004 and May 2009, we retrospectively enrolled 1209 conse...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- JAMA
دوره 297 18 شماره
صفحات -
تاریخ انتشار 2007