Automated serum protein electrophoresis by Capillarys.
نویسندگان
چکیده
Capillary zone electrophoresis (CZE) of serum proteins is increasingly gaining impact in clinical laboratories. In this report, we evaluate automated capillary zone electrophoresis by Capillarys (Sebia, France). Within-run and between-run imprecision for the five electrophoretic fractions was <2% and <6%, respectively. Data obtained with Capillarys correlated with results obtained with agarose gel electrophoresis and Paragon CZE 2000 (Beckman Coulter, USA). Analysis of serum obtained from patients with inflammation, nephrotic syndrome, bisalbuminemia, and alpha1-antitrypsin deficiency revealed that Capillarys was able to detect these abnormalities. Two hundred thirty eight samples were analyzed by agarose gel electrophoresis, Capillarys, capillary electrophoresis using Paragon CZE 2000 system, and immunofixation. Sample selection was based on the presence of a disturbed morphology (e.g., spike) of the protein profile or hypogammaglobulinemia on agarose gel electrophoresis and/or Capillarys. Immunofixation revealed the presence of a monoclonal protein, oligoclonal bands, polyclonal pattern, and a normal profile in, respectively, 89, 66, 19, and 64 samples. With Capillarys, Paragon, and agarose gel electrophoresis, a spike and/or disturbed morphology of the profile was found in 222, 182, and 180 samples, respectively. In these samples, immunofixation was negative in 73 (33%), 46 (25%), and 39 (22%) samples, respectively. These data indicate that Capillarys has a lower specificity than agarose gel electrophoresis and Paragon 2000. Of the 89 samples with a monoclonal protein, Capillarys, Paragon, and agarose gel electrophoresis failed to detect, respectively, three, three, and one monoclonal protein(s). Interferences by radio-opaque agents, complement degradation products, fibrinogen, and triglycerides are described. In conclusion, automated capillary zone electrophoresis with Capillarys provides for reproducible, rapid, and reliable serum electrophoresis.
منابع مشابه
Detection of monoclonal proteins by capillary zone electrophoresis: comparison of 2 multichannel automated systems.
To the Editor: Capillary zone electrophoresis (CZE) is an alternative method for separation of serum proteins (1 ). Two dedicated and automated multichannel instruments are available, the Paragon 2000 (Beckman-Coulter) and the Capillarys (Sebia). The sensitivity and specificity of Paragon 2000 for detection of monoclonal proteins have been reported to be 95% (2–4) and 78% (4 ), respectively. Th...
متن کاملIt's just an illusion.
A 55-year-old man was admitted for impaired health status and lower back pains. Analysis of serum proteins by capillary zone electrophoresis (CZE) was performed on a Capillarys Protein(e) 6. The 1-globulin fraction showed a peak suggestive of the presence of a monoclonal component (Fig. 1A, dashed arrow). However, subsequent serum protein immunotyping (Capillarys Immunotyping) failed to demonst...
متن کاملAutomated multicapillary electrophoresis for analysis of human serum proteins.
BACKGROUND We evaluated a new, automated multicapillary zone electrophoresis (CE) instrument (Capillarys), 4.51 software version; Sebia) for human serum protein analysis. METHODS With the Capillarys beta1-beta2+ reagent set, proteins were separated at 7 kV for 4 min in 15.5 cm x 25 micro m fused-silica capillaries (n = 8) at 35.5 degrees C in a pH 10 buffer with online detection at 200 nm. Se...
متن کاملPerformance of the Sebia CAPILLARYS 2 for detection and immunotyping of serum monoclonal paraproteins.
We evaluated the performance of the CAPILLARYS 2 (Sebia, Norcross, GA) capillary electrophoresis system for detection and identification of monoclonal proteins in serum samples. We analyzed 104 serum specimens by Sebia Hydragel serum protein electrophoresis (agarose gel electrophoresis [AGE]/immunofixation electrophoresis [IFE]) and CAPILLARYS 2 capillary zone electrophoresis (CZE)/immunosubtra...
متن کاملPotential of the Sebia Capillarys neonat fast automated system for neonatal screening of sickle cell disease.
BACKGROUND Most screening programs for sickle cell disease (SCD) utilize isoelectric focusing (IEF) or high performance liquid chromatography (HPLC) to detect haemoglobin (Hb) variants. The first method is not automated and becomes too tedious when many samples have to be investigated. The aim of this work is to explore the capacity of an automated capillary electrophoresis (CE) system, with fu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry and laboratory medicine
دوره 41 5 شماره
صفحات -
تاریخ انتشار 2003