Abstract # 218: Ultrasound Guided Epidural Analgesia for Labour in a Patient with an Intrathecal Baclofen Pump

نویسندگان

  • Manasi Badve
  • M. D. Tanmay Shah
  • M. D. Jeremy Rice
  • D. O. Manuel Vallejo
چکیده

218 Ultrasound Guided Epidural Analgesia for Labour in a Patient with an Intrathecal Baclofen Pump Abstract Type: Case Report/Case Series Manasi Badve, M.D.; Tanmay Shah, M.D.; Jeremy Rice, D.O.; Manuel Vallejo, M.D. Magee-Womens Hospital of UPMCType: Case Report/Case Series Manasi Badve, M.D.; Tanmay Shah, M.D.; Jeremy Rice, D.O.; Manuel Vallejo, M.D. Magee-Womens Hospital of UPMC Intrathecal drug delivery systems for opioids & baclofen are popular for chronic pain and spasticity. Parturients with intrathecal catheter can be a challenge for labor epidural placement. We present a case where ultrasound (US) was used to assist epidural placement in a parturient with intrathecal baclofen pump(ITBP). Case Report: A 44-yr-old woman at 31wks gestation consulted anesthesia to discuss options for childbirth. She developed left spastic hemiplegia from right MCA embolic infarct 6yrs ago. ITBP was placed to control spasticity. Anesthesia choices for vaginal & cesarean delivery were discussed. She opted for labor epidural analgesia. An abdominal X-ray revealed ITBP catheter entering spinal canal between L3-L4 interspace & terminating below T8-9 interspace(Fig). Labor was induced at 37wks gestation & pre-epidural US by an experienced staff anesthesiologist revealed distance from skin to epidural space as 4.3 cm at L1-L2 interspace. A 17-G Tuohy needle was successfully placed at 4 cm to the epidural space in midline on first attempt uneventfully. A single orifice catheter was inserted & fixed at 9cm to skin. Aspiration was negative for CSF. To ensure satisfactory epidural placement, 5mL test dose of lidocaine 1.5% & epinephrine 1:200,000 was given resulting in T8 sensory level and leg numbness. She was hemodynamically stable. Test dose was repeated in active labor & PCEA initiated with 0.083% bupivacaine & 2mcg/ml fentanyl. Labor was uneventful & forceps assisted vaginal delivery was performed. Discussion: Baclofen is an analog of inhibitory neurotransmitter GABA and used to control spasticity of cerebral and spinal origin. ITB is effective in patients unresponsive to traditional drugs or who develop side effects to oral baclofen. Abrupt cessation of ITB can result in life threatening symptoms. Pre-procedure US can identify best interspace for epidural insertion, avoid ITBP catheter shearing,inadvertent dural puncture and failed block. A sterile technique is a must to prevent IT infection and use of antibiotic prophylaxis is unclear. Patient had reduced anesthetic requirement possibly due to preexisting altered sensations due to infarct and/or CSF leaks around ITBP catheter. Conclusion: US guided labor epidural placement in patients with intrathecal drug delivery catheter increases safety margin, neuraxial success rates & avoids complications. References: 1.Int J of Obst Anes2009;18:64-66.2.BMC Clin.Pharmac.2004,4:6:1472-6904/4/6.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Continuous caudal epidural analgesia in a patient with an implanted intrathecal baclofen pump

Introduction: The use of epidural analgesia in patients with implanted intrathecal delivery devices is somewhat controversial. Major concerns include the risk of damaging the intrathecal catheter, the risk of infection, and the potential for interaction between the epidurally-administered and the intrathecally-delivered medication. In children with cerebral palsy, intrathecal administration of ...

متن کامل

Subdural intrathecal catheter placement: experience with two cases.

BACKGROUND Subdural migration of epidural catheters is well known and documented. Subdural placement of intrathecal catheters has not been recognized. Two cases of sudural placement of intrathecal catheters are presented. OBJECTIVE The possibility of subdural migration of epidural catheters and its manifestations has been well documented. The following 2 cases demonstrate that intrathecal cat...

متن کامل

Update on modern neuraxial analgesia in labour: a review of the literature of the last 5 years.

Several strategies and alternative therapies have been used to provide analgesia for labour pain. Over the last few years, a number of improvements have enhanced the efficacy and safety of neuraxial analgesia and ultimately have improved mothers' satisfaction with their birth experience. As labour analgesia is a field of obstetric anaesthesia that is rapidly evolving, this review is an update, ...

متن کامل

Comparison between Continuous Epidural Infusion and Intermittent Epidural Bolus of Bupivacaine Fentanyl Combination for Labour Analgesia

Labour analgesia has become almost synonymous with central neuraxial analgesia. Various techniques are in use from single epidural injection, continuous epidural infusion, combined spinal epidural, patient controlled epidural analgesia to programmed intermittent epidural bolus. Each method has its own advantages and disadvantages though the purpose remains the same:a painless labour and a healt...

متن کامل

Must we press on until a young mother dies? Remifentanil patient controlled analgesia in labour may not be suited as a “poor man’s epidural”

BACKGROUND The epidural route is still considered the gold standard for labour analgesia, although it is not without serious consequences when incorrect placement goes unrecognized, e.g. in case of intravascular, intrathecal and subdural placements. Until now there has not been a viable alternative to epidural analgesia especially in view of the neonatal outcome and the need for respiratory sup...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011