Determination of melamine based on electrochemiluminescence of Ru(bpy)3(2+) at bare and single-wall carbon nanotube modified glassy carbon electrodes.

نویسندگان

  • Fengyu Liu
  • Xue Yang
  • Shiguo Sun
چکیده

The electrochemiluminescence (ECL) of Ru(bpy)(3)(2+) at bare and single-wall carbon nanotube (SWNT) modified glassy carbon (GC) electrodes has been employed for the determination of melamine for the first time, giving a linear response (R(2) = 0.99682) for melamine concentration from 1.0 × 10(-10) to 1.0 × 10(-5) M at a bare GC electrode in pH 10 borate buffer, and the detection limit is 1.0 × 10(-10) M. However, the detection limit can be reduced further to 1.0 × 10(-13) M after modification of the GC electrode by SWNTs. This is much lower compared to other detection methods. The proposed method was applied to the determination of melamine added to a commercial milk sample; the recovery is quite satisfactory with good reproducibility and stability. All of these results provide the possibility of developing a novel ECL detection method for melamine.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Novel Poly-Dopamine Adhesive for a Halloysite Nanotube-Ru(bpy)32+ Electrochemiluminescent Sensor

Herein, for the first time, the electrochemiluminescent sensor based on Ru(bpy)(3) (2+)-modified electrode using dopamine as an adhesive was successfully developed. After halloysite nanotube slurry was cast on a glassy carbon electrode and dried, an alkaline dopamine solution was added on the electrode surface. Initially, polydopamine belts with dimensions of tens to hundreds of nanometers form...

متن کامل

Electrochemical Sensor for Determination of Fenitrothion at Multi-wall Carbon Nanotubes Modified Glassy Carbon Electrode

A sensor, based on multi-wall carbon nanotubes modified glassy carbon electrode (MWCNT/GCE), was developed for determination of fenitrothion. Determining the surface area of MWCNT/GCE showed that this surface is three times more active than that of a glassy carbon electrode. The experimental parameters, such as the amount of MWCNTs, pH of the fenitrothion solution, preconcentration potential an...

متن کامل

Adsorptive Behavior and Voltammetric Determination of Hydralazine Hydrochloride at A Glassy Carbon Electrode Modified with Multiwalled Carbon Nanotubes

An electroanalytical method has been introduced for highly sensitive determination of hydralazine hydrochloride (Hy-HCl) based on its oxidation at a glassy carbon electrode modified with multiwalled carbon nanotubes (MWCNT/GCE). Studies showed that the electrochemical oxidation of Hy-HCl was accompanied by adsorption and highly sensitive responses could be achieved by adsorptive stripping volta...

متن کامل

Adsorptive Behavior and Voltammetric Determination of Hydralazine Hydrochloride at A Glassy Carbon Electrode Modified with Multiwalled Carbon Nanotubes

An electroanalytical method has been introduced for highly sensitive determination of hydralazine hydrochloride (Hy-HCl) based on its oxidation at a glassy carbon electrode modified with multiwalled carbon nanotubes (MWCNT/GCE). Studies showed that the electrochemical oxidation of Hy-HCl was accompanied by adsorption and highly sensitive responses could be achieved by adsorptive stripping volta...

متن کامل

Simultaneous Voltammetric Measurement of Ascorbic Acid, Epinephrine, Uric Acid and Tyrosine at a Glassy Carbon Electrode Modified with Nanozeolite-Multiwall Carbon Nanotube

In this study, incorporation of iron ion-doped natrolite nanozeolite, multi-wall carbon nanotubes into chitosan-coated glassy carbon electrode for the simultaneous determination of ascorbic acid, epinephrine, uric acid and tyrosine is studied. The results show that the combination of multi-wall carbon nanotubes and iron ion-doped natrolite zeolite causes a dramatic enhancement in the sensitivit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 136 2  شماره 

صفحات  -

تاریخ انتشار 2011