Aspirate from human stented native coronary arteries vs. saphenous vein grafts: more endothelin but less particulate debris.
نویسندگان
چکیده
Stent implantation into atherosclerotic coronary arteries releases particulate debris and soluble substances that contribute to impaired microvascular perfusion. Here we addressed the potential for microvascular obstruction in patients with stenotic native right coronary arteries (nRCA) compared with saphenous vein grafts on right coronary arteries (SVG-RCA). We enrolled symptomatic, male patients with stable angina pectoris and a flow-limiting stenosis in their nRCA or SVG-RCA (n = 18/18). Plaque volume and composition were analyzed using intravascular ultrasound before stent implantation. Coronary aspirate was retrieved during stent implantation under protection with a distal occlusion/aspiration device and divided into particulate debris and plasma. The release of catecholamines, endothelin, serotonin, thromboxane B2, and tumor necrosis factor-α was measured. The response of rat mesenteric arteries with intact (+E) and denuded (-E) endothelium to aspirate plasma (without and with selective endothelin receptor blockade) was normalized to that by potassium chloride (KClmax = 100%). Plaque volume and composition were not different between nRCA and SVG-RCA. There was less particulate debris (65 ± 8 vs. 146 ± 23 mg; P < 0.05) and more endothelin release (5.8 ± 0.8 vs. 1.3 ± 0.7 pg/ml; P < 0.05) in nRCA than in SVG-RCA, whereas the release of the other mediators was not different. Aspirate from nRCA induced stronger vasoconstriction than that from SVG-RCA [nRCA, 78 ± 6% (+E)/84 ± 5% (-E); SVG-RCA, 59 ± 6% (+E)/68 ± 3% (-E); P < 0.05 nRCA vs. SVG-RCA], which was attenuated by a nonspecific endothelin and a specific endothelin receptor A antagonist. Thus coronary aspirate from stented nRCA is characterized by less debris but more endothelin and stronger vasoconstrictor response than that from SVG-RCA.
منابع مشابه
TRANSLATIONAL PHYSIOLOGY Aspirate from human stented native coronary arteries vs. saphenous vein grafts: more endothelin but less particulate debris
Kleinbongard P, Baars T, Möhlenkamp S, Kahlert P, Erbel R, Heusch G. Aspirate from human stented native coronary arteries vs. saphenous vein grafts: more endothelin but less particulate debris. Am J Physiol Heart Circ Physiol 305: H1222–H1229, 2013. First published August 9, 2013; doi:10.1152/ajpheart.00358.2013.—Stent implantation into atherosclerotic coronary arteries releases particulate deb...
متن کاملAspirate from human stented saphenous vein grafts induces epicardial coronary vasoconstriction and impairs perfusion and left ventricular function in rat bioassay hearts with pharmacologically induced endothelial dysfunction
Stent implantation into aortocoronary saphenous vein grafts (SVG) releases particulate debris and soluble vasoactive mediators, for example, serotonin. We now analyzed effects of the soluble mediators released into the coronary arterial blood during stent implantation on vasomotion of isolated rat epicardial coronary artery segments and on coronary flow and left ventricular developed pressure i...
متن کاملIntense vasoconstriction in response to aspirate from stented saphenous vein aortocoronary bypass grafts.
OBJECTIVES We sought to identify soluble vasoconstrictor substances that are released during stent implantation into saphenous vein aortocoronary bypass grafts. BACKGROUND Atherosclerotic saphenous vein aortocoronary bypass grafts are particularly vulnerable to plaque rupture. Protection devices prevent particulate debris from being embolized. Additional soluble vasoconstrictor substances pos...
متن کاملVasoconstrictor potential of coronary aspirate from patients undergoing stenting of saphenous vein aortocoronary bypass grafts and its pharmacological attenuation.
RATIONALE Stent implantation into atherosclerotic plaques releases, apart from particulate debris, soluble substances that contribute to impaired microvascular perfusion. OBJECTIVE To quantify the release of vasoconstrictors and to determine the efficacy of coronary dilators to attenuate their action. METHODS AND RESULTS Using a distal protection/aspiration device, coronary arterial blood w...
متن کاملRelease of Intracoronary Microparticles during Stent Implantation into Stable Atherosclerotic Lesions under Protection with an Aspiration Device
OBJECTIVE Stent implantation into atherosclerotic coronary vessels impacts on downstream microvascular function and induces the release of particulate debris and soluble substances, which differs qualitatively and quantitatively between native right coronary arteries (RCAs) and saphenous vein grafts on right coronary arteries (SVG-RCAs). We have now quantified the release of microparticles (MPs...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- American journal of physiology. Heart and circulatory physiology
دوره 305 8 شماره
صفحات -
تاریخ انتشار 2013