End-bearing characteristics of patellar-tendon-bearing prosthesis--a preliminary report.
نویسندگان
چکیده
The present work was aimed at investigating the degree of participation of the stump end in the weightbearing process in PTB prostheses. Despite the belief that the stump end is not capable of withstanding high loads, it was revealed that most patients can bear from 15 percent up to 45 percent and more of their weight on the stump end. The limited number of patients studied diminishes the statistical significance, but the results of this work do suggest that the weightbearing mechanism of a PTB prosthesis can be further improved by transferring more load through the stump end. It is suggested that a nondestructive technique for assessing the end-bearing efficiency of the prosthesis be developed. Also, the criteria for design of the socket end in order to produce the desired load-bearing features needs further investigation.
منابع مشابه
A new surgical-prosthetic approach to the Syme's amputation, a preliminary report.
The advantage of the end-bearing ankledisarticulation amputation has been well recognized since Syme published his classic article in 1843 (2). Disadvantages and complications of this level of amputation have led some surgeons to favor amputation at a higher level. Failure of adherence of the heel pad to the distal tibia, resulting in a flabby, loose stump, prevents many amputees from ambulatin...
متن کاملDevelopment of Refined Fitting Procedures for Lower-extremity Prosthese
With the development of the patellar-tendon-bearing prosthesis by the University of California at Berkeley, many new advantages in simplicity, comfort, and function were available to the below-knee amputee. However, there still exists the problem of concentrated pressures over small areas of the stump. The original design of the patellar-tendonbearing prosthesis was intended to distribute the l...
متن کاملThe Army Medical Biomechanical Research Laboratory porous laminate patellar-tendon-bearing prosthesis.
1 Based upon The AMBRL Porous Laminate Patellar Tendon-Bearing Prosthesis, published by Prosthetics and Orthotics, New York University Post-Graduate Medical School, New York, NY. , in March 1968 (1). The study was conducted under the supervision of Sidney Fishman, Ph.D., Project Director, with financial support from a special grant from the Children's Bureau, Department of Health, Education, an...
متن کاملSeated-popliteal weight bearing prosthesis for a bilateral amputee.
Bilateral lower limb amputees suffer from a lack of stability when seated without prostheses due to lack of ground reaction forces through the stumps. In patients for whom ambulation is not a realistic goal, the seated-popliteal weight bearing prosthesis provides a solution for stability when seated in a wheelchair, without the problem of tibial pressure experienced with patellar-tendon-bearing...
متن کاملThe evolution of functional bracing of fractures.
©2006 British Editorial Society of Bone and Joint Surgery doi:10.1302/0301-620X.88B2. 16381 $2.00 J Bone Joint Surg [Br] 2006;88-B:141-8. Functional fracture bracing, described in 1967, 1 was inspired by the patellar-tendonbearing prosthesis which had recently been developed for below-knee amputees. This prosthesis had eliminated the traditional thigh corset and allowed the transfer of weight-b...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Bulletin of prosthetics research
دوره 16 2 شماره
صفحات -
تاریخ انتشار 1979