Inverse Cutting of Posterior Lamellar Corneal Grafts by a Femtosecond Laser

نویسندگان

  • Jesper Hjortdal
  • Esben Nielsen
  • Anders Vestergaard
  • Anders Søndergaard
چکیده

PURPOSE Posterior lamellar grafting of the cornea has become the preferred technique for treatment of corneal endothelial dysfunction. Posterior lamellar grafts are usually cut by a micro-keratome or a femto-second laser after the epithelial side of the donor cornea has been applanated. This approach often results in variable central graft thickness in different grafts and an increase in graft thickness towards the periphery in every graft. The purpose of this study was to evaluate if posterior lamellar grafts can be prepared from the endothelial side by a femto-second laser, resulting in reproducible, thin grafts of even thickness. METHODS A CZM 500 kHz Visumax femto-second laser was used. Organ cultured donor grafts were mounted in an artifical anterior chamber with the endothelial side up and out. Posterior grafts of 7.8 mm diameter and 130 micron thickness were prepared by femto-second laser cutting. A standard DSAEK procedure was performed in 10 patients with Fuchs endothelial dystrophy. Patients were followed-up regularly and evaluated by measurement of complications, visual acuity, corneal thickness (Pentacam HR), and endothelial cell density. RESULTS Femto-laser cutting of grafts and surgery was uncomplicated. Rebubbling was necessary in 5 of 10 cases (normally only in 1 of 20 cases). All grafts were attached and cleared up during the first few weeks. After six months, the average visual acuity was 0.30 (range: 0.16 to 0.50), corneal thickness was 0.58 mm (range 0.51 to 0.63), and endothelial cell density was 1.570 per sq. mm (range: 1.400 to 2.000 cells per sq. mm). The grafts were of uniform thickness, but substantial interface haze was present in most grafts. CONCLUSIONS Posterior lamellar corneal grafts can be prepared from the endothelial side using a femto-second laser. All grafts were clear after 6 months with satisfying endothelial cell counts. Poor visual acuity caused by interface scatter was observed in most patients. Femto-second laser cutting parameters needs to be optimised to enable smooth cutting in the posterior stroma.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Microkeratome versus femtosecond laser predissection of corneal grafts for anterior and posterior lamellar keratoplasty.

PURPOSE To compare 2 different techniques for predissection of human anterior and posterior lamellar corneal grafts for eye bank storage. METHODS A mechanical microkeratome (group 1, N = 5) and a femtosecond laser (group 2, N = 5) were used to dissect intended 350-microm-deep lamellar planes in deepithelialized donor corneas mounted on an artificial anterior chamber. These corneas were replac...

متن کامل

Preparing Uniform-Thickness Corneal Endothelial Grafts from Donor Tissues Using a Non-Amplified Femtosecond Laser

Corneal grafts for Descemet's Stripping Automated Endothelial Keratoplasty are commonly prepared using mechanical microkeratomes. However, the cuts produced in such way render corneal lenticules that are thinner centrally than peripherally, thus inducing a hyperopic shift. Here we describe a novel device for preparing donor corneal grafts, in which a single low-energy femtosecond laser system i...

متن کامل

Analysis of low-energy and high-frequency femtosecond laser for the construction of deep anterior donor corneal lamellae Laser de femtossegundo de baixa energia e alta frequência na confecção de lamelas corneanas doadoras

Purpose: To evaluate the efficacy and reliability of a low-energy femtosecond laser with a high repetition rate for construction of deep anterior donor corneal lamellae. Methods: This was a prospective laboratory investigation. Twenty-five human corneal buttons were femtosecond laser cut to create thick anterior lamellae (diameter, 10mm; thickness, 500μm). The laser cuts were made using an LDV ...

متن کامل

Cataract Surgery Bonus Feature

NOVEMBER/DECEMBER 2010 CATARACT & REFRACTIVE SURGERY TODAY EUROPE 23 F ull-thickness penetrating keratoplasty (PKP) has been the preferred corneal transplantation technique since the procedure was first described in 1905 by Eduard Zirm.1 Today, PKP generally results in clear corneal grafts, with a graft survival rate of up to 72% at 5 years.2 However, the procedure is frequently complicated by ...

متن کامل

Surface quality of femtosecond dissected posterior human corneal stroma investigated with atomic force microscopy.

PURPOSE To investigate and compare the surface roughness and morphology of posterior stromal lenticules created with a femtosecond laser using various pulse energies to that obtained with a mechanical microkeratome. METHODS A 150 kHz femtosecond laser platform (IntraLase iFS; Abbott Medical Optics) was programmed to create an 8.5-mm-diameter posterior stromal lenticule in 12 human corneal tis...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 6  شماره 

صفحات  -

تاریخ انتشار 2012