[Simultaneous determination of chlorhexidine acetate and benzalkonium chloride in compound chemical disinfectants by capillary electrophoresis].
نویسندگان
چکیده
Benzalkonium chloride (BAC) is a mixture of alkyl substituted benzyl dimethylammonium chloride homologs (C12-BAC, C14-BAC and C16-BAC). Chlorhexidine acetate is a widely used effective component in compound chemical disinfectants. A method for the simultaneous determination of chlorhexidine acetate and benzalkonium chloride in compound chemical disinfectants by capillary electrophoresis (CE) was established. The CE analysis was carried out using an uncoated capillary with 50 microm i. d. and 37 cm total length. The running buffer was 150 mmol/L NaH2PO4-62.5 mmol/L H3PO4 (pH 2.5) containing 40% (v/v) acetonitrile. The sample medium was 50 mmol/L acetic acid-acetonitrile (1:1, v/v). The detection wavelength was 214 nm. The factors such as the buffer concentration and pH, the content of acetonitrile, which influenced the separation and accurate assay of compound chemical disinfectants were investigated in detail. The intra-day and inter-day precisions of the method were below 3. 0% and 3.7%, respectively. The limits of detection (LOD, signal to noise ratio (S/N) = 3) for chlorhexidine acetate, C12-BAC, Cl4-BAC and C16-BAC were 0. 3, 0.5, 0.5 and 0.5 mg/L, respectively. The limits of quantification (LOQ, S/N = 10) were 1.0, 1.5, 1.5, and 1.5 mg/L, respectively. The corrected peak area and the mass concentration of the four components mentioned above showed good linear relationships within the ranges of 1.0 - 400 mg/L, 1. 5 - 200 mg/L, 1.5 - 200 mg/L and 1.5 - 200 mg/L, with linear correlation coefficients (r) of 0.9995, 0.9998, 0.999 7 and 0.9998, respectively. The established method was used for the determination of the four disinfectants in the compound chemical disinfectants. The results were in good agreement with those obtained by the high performance liquid chromatographic method.
منابع مشابه
Study of the Interactions Between Bacteriophage phiIPLA-RODI and Four Chemical Disinfectants for the Elimination of Staphylococcus aureus Contamination
Bacteriophages are currently considered as a promising alternative to antibiotics and disinfectants. However, the use of phages in different clinical and industrial settings will involve their exposure to other disinfectants. As a result, the outcome of the phage treatment will depend on two aspects derived from such interactions. On the one hand, the susceptibility of the phage to disinfectant...
متن کاملفعالیت ضدّ قارچی ضدّ عفونیکنندهها روی عوامل قارچی ساپروفیت جداشده از محیط و اتاق جراحی در کلینیکهای بخش خصوصی تهران
Background and Aim: Due to increasing of fungal infections and isolation of fungal agents from different surgery sites and Intensive Care Units, the administration of effective disinfectants is essential. The present study was done to evaluate antifungal activity of various disinfectants on fungi isolated from the environment and surgery rooms in private clinics in Tehran between 2011 and 2012....
متن کاملInduction of mexCD-oprJ operon for a multidrug efflux pump by disinfectants in wild-type Pseudomonas aeruginosa PAO1.
Induction of the MexCD-OprJ multidrug efflux pump was investigated in wild-type Pseudomonas aeruginosa PAO1. MexCD-OprJ was induced by clinically important disinfectants such as benzalkonium chloride and chlorhexidine gluconate, and by some cytotoxic agents such as tetraphenylphosphonium chloride, ethidium bromide and rhodamine 6G. MexCD-OprJ was not induced by norfloxacin, tetracycline, chlora...
متن کاملCorrelation between reduced susceptibility to disinfectants and multidrug resistance among clinical isolates of Acinetobacter species.
BACKGROUND The aim of this study was to investigate the susceptibility profiles to disinfectants and antimicrobial agents of 283 non-repetitive Acinetobacter clinical isolates obtained in 97 Japanese hospitals in March 2002. METHODS Susceptibility profiles of the above isolates to four disinfectants, six antimicrobial agents and two dyes were investigated. MICs were measured by the agar dilut...
متن کاملChlorhexidine loss from simulated contact lens solutions stored in glass and plastic packages.
A storage test on chlorhexidine gluconate (0.004%) in aqueous or simulated contact lens solutions, conducted for 6 months in various containers, suggested [l] that loss of activity by a surface adsorption process was occurring. It has been reported [2] that contact lens solutions containing chlorhexidine gluconate (0.~5%) stored at room temperature in the dark for 6 months in polypropylene, pol...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Se pu = Chinese journal of chromatography
دوره 30 9 شماره
صفحات -
تاریخ انتشار 2012