Use of heated humidification during nasal CPAP titration in obstructive sleep apnoea syndrome.

نویسندگان

  • M Duong
  • L Jayaram
  • D Camfferman
  • P Catcheside
  • I Mykytyn
  • R D McEvoy
چکیده

Nasal symptoms associated with the use of nasal continuous positive airway pressure (nCPAP) in obstructive sleep apnoea (OSA) can adversely impact on patients' tolerance, acceptance and adherence to nCPAP therapy. Regular use of heated humidification is effective in alleviating these symptoms and improve patient comfort. In a randomised, parallel, double-blinded, controlled study, the present authors examined the use of heated humidification during a single night laboratory nCPAP titration in untreated OSA patients and its effect on nasal symptoms, nasal airway resistance (NAR), effective pressure and treatment tolerability and acceptance. Baseline characteristics of subjects (n=70) receiving placebo and humidification were (mean+/-sem): age 51.2+/-2.2 versus 50.6+/-1.6 yrs; body mass index 33.6+/-0.9 versus 35.2+/-0.9 kg.m-2; Epworth Sleepiness Scale 10.8+/-1.0 versus 11.3+/-0.7; and apnoea-hypopnoea index 43.5+/-4.6 versus 44.4+/-4.1 events.h-1. Total inspiratory NAR, before (0.36+/-0.09 (placebo) versus 0.33+/-0.09 kPa.L-1.s-1) and after nCPAP (0.47+/-0.11 versus 0.29+/-0.04 kPa.L-1.s-1) were not significantly different between the groups. No difference was found in the frequency and severity of nasopharyngeal symptoms, therapeutic pressure and subjective response to nCPAP. In conclusion, heated humidification during the initial nasal continuous positive airway pressure titration offers no additional benefit in nasal physiology, symptoms or subjective response to nasal continuous positive airway pressure, and, therefore, should not be routinely recommended.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Nasal inflammation in sleep apnoea patients using CPAP and effect of heated humidification.

Nasal continuous positive airway pressure (CPAP) can cause undesirable nasal symptoms, such as congestion to obstructive sleep apnoea (OSA) patients, whose symptoms can be attenuated by the addition of heated humidification. However, neither the nature of nasal symptoms nor the effect of heated humidification on nasal pathophysiology and pathology are convincingly known. 20 patients with OSA on...

متن کامل

Impact of a controlled heated breathing tube humidifier on sleep quality during CPAP therapy in a cool sleeping environment.

There are conflicting data on the effect of adding a heated humidifier to nasal continuous positive airway pressure (CPAP) therapy for patients with obstructive sleep apnoea syndrome (OSAS). The effects of heated humidification on sleep quality and treatment side-effects for patients who prefer a cold bedroom environment have not been studied. A randomised, controlled crossover trial involving ...

متن کامل

Humidified nasal continuous positive airway pressure in obstructive sleep apnoea.

Heated humidification of nasal continuous positive airway pressure (nCPAP) reduces upper airway symptoms and improves initial use in obstructive sleep apnoea syndrome (OSAS). The present study aimed to assess the effect of heated humidification of nCPAP on upper airway symptoms and initial use in obstructive sleep apnoea. This study was of a randomised, crossover design. Subjects with polysomno...

متن کامل

Heated humidification or face mask to prevent upper airway dryness during continuous positive airway pressure therapy.

STUDY OBJECTIVES The objectives of this study were (1) to evaluate the way in which nasal continuous positive airway pressure (CPAP) therapy influences the relative humidity (rH) of inspired air; and (2) to assess the impact on rH of the addition of an integrated heated humidifier or a full face mask to the CPAP circuitry. DESIGN The studies were performed in 25 patients with obstructive slee...

متن کامل

Effect of heated humidification on compliance and quality of life in patients with sleep apnea using nasal continuous positive airway pressure.

STUDY OBJECTIVE To determine whether the addition of heated humidification at treatment initiation with nasal continuous positive airway pressure (CPAP) would lead to better CPAP compliance and improve quality of life and subjective sleepiness in patients with sleep apnea. DESIGN Randomized controlled trial. SETTING An academic sleep center located at a Veterans Affairs hospital. PATIENTS...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 26 4  شماره 

صفحات  -

تاریخ انتشار 2005