Comparison of the Quantiplex version 3.0 assay and a sensitized Amplicor monitor assay for measurement of human immunodeficiency virus type 1 RNA levels in plasma samples.

نویسندگان

  • H C Highbarger
  • W G Alvord
  • M K Jiang
  • A S Shah
  • J A Metcalf
  • H C Lane
  • R L Dewar
چکیده

This study evaluated correlation and agreement between version 3 of the Quantiplex human immunodeficiency virus type 1 (HIV-1) RNA assay (v3 branched DNA [bDNA]) and a sensitized Amplicor HIV-1 Monitor assay (reverse transcription [RT]-PCR) for the measurement of HIV RNA. Three hundred eighteen samples from 59 randomly selected, HIV-1-seropositive persons on various drug protocols from the National Institute of Allergy and Infectious Diseases HIV outpatient clinic were studied. The results indicate that v3 bDNA and RT-PCR are highly correlated (r = 0.98) and are in good agreement (mean difference in log(10) copies/ml +/- 2 standard deviations = 0.072 +/- 0.371). The relationship between values obtained by both assays is given by the following equation: log(10)v3 bDNA = -0.0915 + 1. 0052. log(10)RT-PCR. This represents a 1.026-fold difference between log(10)RT-PCR values and log(10)v3 bDNA values.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the QUANTIPLEX HIV-1 RNA 2.0 assay with the AMPLICOR HIV-1 MONITOR 1.0 assay for quantitation of levels of human immunodeficiency virus type 1 RNA in plasma of patients receiving stavudine-didanosine combination therapy.

We compared the QUANTIPLEX HIV-1 RNA 2.0 assay with the AMPLICOR HIV-1 MONITOR 1.0 assay for quantitation of human immunodeficiency virus type 1 (HIV-1) RNA in plasma in the Stadi trail, which evaluated a stavudine plus didanosine combination therapy in 52 patients. HIV-1 RNA baseline values measured with AMPLICOR HIV-1 MONITOR 1.0 were significantly higher than those measured with QUANTIPLEX H...

متن کامل

Comparative performance of three viral load assays on human immunodeficiency virus type 1 (HIV-1) isolates representing group M (subtypes A to G) and group O: LCx HIV RNA quantitative, AMPLICOR HIV-1 MONITOR version 1.5, and Quantiplex HIV-1 RNA version 3.0.

The performance of the LCx HIV RNA Quantitative (LCx HIV), AMPLICOR HIV-1 MONITOR version 1.5 (MONITOR v1.5), and Quantiplex HIV-1 RNA version 3.0 (bDNA v3.0) viral load assays was evaluated with 39 viral isolates (3 A, 7 B, 6 C, 4 D, 8 E, 4 F, 1 G, 4 mosaic, and 2 group O). Quantitation across the assay dynamic ranges was assessed using serial fivefold dilutions of the viruses. In addition, se...

متن کامل

Performance characteristics of the QUANTIPLEX HIV-1 RNA 3.0 assay for detection and quantitation of human immunodeficiency virus type 1 RNA in plasma.

The QUANTIPLEX HIV-1 RNA assay, version 3.0 (a branched DNA, version 3.0, assay [bDNA 3.0 assay]), was evaluated by analyzing spiked and clinical plasma samples and was compared with the AMPLICOR HIV-1 MONITOR Ultrasensitive (ultrasensitive reverse transcription-PCR [US-RT-PCR]) method. A panel of spiked plasma samples that contained 0 to 750,000 copies of human immunodeficiency virus type 1 (H...

متن کامل

Use of active surveillance cultures in intensive care units.

3. Katsoulidou A, Petrodaskalaki M, Sypsa V, et al. Evaluation of the clinical sensitivity for the quantitation of human immunodeficiency virus type 1 RNA in plasma: comparison of the new Cobas TaqMan HIV-1 with three current HIV-RNA assays–LCx HIV RNA quantitative, Versant HIV-1 RNA 3.0 (bDNA) and Cobas Amplicor HIV-1 Monitor v1.5. J Virol Methods 2006; 131:168–74. 4. Damond F, Roquebert B, Be...

متن کامل

Comparison of the Amplicor HIV-1 monitor test and the nucleic acid sequence-based amplification assay for quantitation of human immunodeficiency virus RNA in plasma, serum, and plasma subjected to freeze-thaw cycles.

The Amplicor HIV-1 Monitor test was compared to the nucleic acid sequence-based amplification (Nasba) assay system for the quantitation of human immunodeficiency virus (HIV) RNA in three different types of clinical samples: plasma, serum, and plasma subjected to freeze-and-thaw cycles. Each assay detected HIV RNA in the same 73 (90%) of 81 samples tested, and the quantitative results obtained w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 37 11  شماره 

صفحات  -

تاریخ انتشار 1999