Improving Nanopore Reads Raw Signal Alignment

نویسندگان

  • Vladim'ir Bovza
  • Brovna Brejov'a
  • Tom'avs Vinavr
چکیده

We investigate usage of dynamic time warping (DTW) algorithm for aligning raw signal data from MinION sequencer. DTW is mostly using for fast alignment for selective sequencing to quickly determine whether a read comes from sequence of interest. We show that standard usage of DTW has low discriminative power mainly due to problem with accurate estimation of scaling parameters. We propose a simple variation of DTW algorithm, which does not suffer from scaling problems and has much higher discriminative power.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Nanopore sequencing detects structural variants in cancer.

Despite advances in sequencing, structural variants (SVs) remain difficult to reliably detect due to the short read length (<300 bp) of 2nd generation sequencing. Not only do the reads (or paired-end reads) need to straddle a breakpoint, but repetitive elements often lead to ambiguities in the alignment of short reads. We propose to use the long-reads (up to 20 kb) possible with 3rd generation ...

متن کامل

Characterization, correction and de novo assembly of an Oxford Nanopore genomic dataset from Agrobacterium tumefaciens

The MinION is a portable single-molecule DNA sequencing instrument that was released by Oxford Nanopore Technologies in 2014, producing long sequencing reads by measuring changes in ionic flow when single-stranded DNA molecules translocate through the pores. While MinION long reads have an error rate substantially higher than the ones produced by short-read sequencing technologies, they can gen...

متن کامل

Improved assembly of noisy long reads by k-mer validation.

Genome assembly depends critically on read length. Two recent technologies, from Pacific Biosciences (PacBio) and Oxford Nanopore, produce read lengths >20 kb, which yield de novo genome assemblies with vastly greater contiguity than those based on Sanger, Illumina, or other technologies. However, the very high error rates of these two new technologies (∼15% per base) makes assembly imprecise a...

متن کامل

Annotated mitochondrial genome with Nanopore R 9 signal for

a nematode parasite of rodents, has a parasitic Nippostrongylus brasiliensis life cycle that is an extremely useful model for the study of human hookworm infection, particularly in regards to the induced immune response. The current reference genome for this parasite is highly fragmented with minimal annotation, but new advances in long-read sequencing suggest that a more complete and annotated...

متن کامل

LINKS: Scalable, alignment-free scaffolding of draft genomes with long reads

BACKGROUND Owing to the complexity of the assembly problem, we do not yet have complete genome sequences. The difficulty in assembling reads into finished genomes is exacerbated by sequence repeats and the inability of short reads to capture sufficient genomic information to resolve those problematic regions. In this regard, established and emerging long read technologies show great promise, bu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017