Radiotherapy is one of the main treatment modalities to treat cancer. Image based treatment verification has been recently introduced. However, a quantitative comparison between the planned and delivered dose is a novel development in the field of radiotherapy. In this thesis, the added value of quantitative in-treatment dose measurements techniques to facilitate adaptive radiotherapy has been investigated. Several methods have been developed for in-treatment dose verification: 1) Planar dose verification; 2) 3D dose verification; and 3) Time-resolved dose verification. The thesis therefore is divided into two parts, part one where novel technologies were developed to compare dose distributions in 3D and compare time-resolved dose distributions. In part two, the clinical applications and the advantages of dose guided radiotherapy are studied. In chapter 2, the calculation of dose differences was optimized for processing on a graphics processing chip resulting in sub-second calculations times. In chapter 3, the calculation has been optimized to analyze and compare time-resolved dose information. The current method (the gamma calculation) has been extended with an extra degree of freedom; besides dose differences and spatial differences, temporal differences are considered. This results in a method which can accurately evaluate time-resolved dose information. In part, two planar dosimetry has been investigated for 3D conformal radiotherapy. A method was developed to divide inter-fractional differences into random and systematic differences (chapter 4). This difference was essential to improve performance of informed decision making for adaptive radiotherapy. It is the systematic dose difference where one would like to act upon while random differences may usually be ignored. The planar dose verification research proceeded with an investigation to the advanced rotational therapy VMAT in chapter 5. A correlation was sought between relevant dose differences in the 3D dose distribution based upon dose volume histograms metrics and dose differences measured with integrated planar portal dosimetry, but none was found. In chapter 6 therefore, the advantages of 3D portal dosimetry for lung cancer patients was investigated. Lung cancer was investigated because in a large number of patients relevant geometrical changes can occur during treatment. Advanced 3D portal dosimetry has many advantages for lung cancer patients and therefore adapt the treatment accordingly. In the final chapter of this thesis (chapter 7), a novel time-resolved in-treatment planar dose verification method has been investigated as a continuation on the negative results of chapter 5. The aim was to see if time-resolved portal dosimetry delivers more accurate and robust results. In this study, several cases were analyzed to investigate the advantages of this novel method in comparison with time-integrated portal dosimetry. The study showed a great potential for time-resolved portal dosimetry for VMAT treatments. In summary, it was shown that for the different verification methods for the clinical application, the use of quantitative dose information is useful for informed decision making for adaptive radiotherapy. References to author publications that relate specifically to the dissertation: 1. L.C.G.G. Persoon, M. Podesta, W.J.C. van Elmpt, S.M.J.J.G. Nijsten, and F. Verhaegen, “A fast three-dimensional gamma evaluation using a GPU utilizing texture memory for on-the-fly interpolations”, Medical Physics 38(7):4032-4035 (2011) 2. L.C.G.G. Persoon, S.M.J.J.G. Nijsten, F.J. Wilbrink, M. Podesta, J.A.D. Snaith, T. Lustberg, W.J.C. van Elmpt, F. van Gils, F. Verhaegen, “Interfractional trend analysis of dose differences based on 2D transit portal dosimetry”, Physics in Medicine and Biology, 57(20): 6445-6458 (2012) 3. L.C.G.G. Persoon, A.G.T.M. Egelmeer, M.C. Ollers, S.M.J.J.G. Nijsten, E.G.C. Troost, F. Verhaegen, “First clinical results of adaptive radiotherapy based on 3D portal dosimetry for lung cancer patients with atelectasis treated with volumetricmodulated arc therapy (VMAT).”, Acta Oncologica, 52(7):1484-9 (2013) 4. M. Podesta, L.C.G.G. Persoon, F. Verhaegen, “A novel time dependent gamma evaluation function for dynamic 2D and 3D dose distributions.”, Physics in Medicine and Biology, 59(20):5973-85 (2014) 5. L.C.G.G. Persoon, M. Podesta, L. Hoffmann, A. Sanizadeh, L.E.J.R. Schyns, B.M. de Ruiter, S.M.J.J.G. Nijsten, L.P. Muren, E.G.C. Troost, F. Verhaegen, “Is integrated transit planar portal dosimetry able to detect geometric changes in lung cancer patients treated with volumetric modulated arc therapy?”, Acta Oncologica, 16:1-7 (2015) 6. L.C.G.G. Persoon, M. Podesta, S.M.J.J.G. Nijsten, E.G.C. Troost, F. Verhaegen, “TimeResolved versus Integrated Transit Planar Dosimetry for Volumetric Modulated Arc Therapy: Patient-Specific Dose Differences During Treatment, a Proof of Principle”, Technology in Cancer Research & Treatment, 15(6):NP79-NP87 (2015)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Verification of Monitor unit calculations for eclipse Treatment Planning System by in- house developed spreadsheet

Introduction: Computerized treatment planning is a rapidly evolving modality that depends on hardware and software efficiency. Despite ICRU recommendations suggesting 5% deviation in dose delivery the overall uncertainty shall be less than 3.5% as suggested by B.J. Minjnheer. J. In house spreadsheets are developed by the medical physicists to cross-verify the dose calculated by the Treatment Pl...

متن کامل

Point Dose Measurement for Verification of Treatment Planning System using an Indigenous Heterogeneous Pelvis Phantom for Clarkson, Convolution, Superposition, and Fast Superposition Algorithms

Background: Nowadays, advanced radiotherapy equipment includes algorithms to calculate dose. The verification of the calculated doses is important to achieve accurate results. Mostly homogeneous dosimetric phantoms are available commercially which do not mimic the actual patient anatomy; therefore, an indigenous heterogeneous pelvic phantom mimicking actual human pelvic region has been used to ...

متن کامل

Verification of delivered dose to the Lips carcinoma tumors with HDR brachytherapy sources: 192Ir and 60CO in an exclusive plexiglass Phantom.

Introduction: Brachytherapy, especially using manually after loaded Iridium-192 and Cobalt-60, can be applied as a sole treatment, as a treatment complementary to surgery, and as a local boost in combination with EBRT. The use of HDR brachytherapy catheters incorporated in removable dental molds allows repeated, highly reproducible, fractionated outpatient brachytherapy of supe...

متن کامل

Comparative Study between Electronic Portal Imaging Device (EPID) and Cone Beam Computed Tomography (CBCT) for Radiation Treatment Verifications

Introduction: Electronic Portal Imaging Device (EPID) and Cone Beam Computed Tomography (CBCT) are the preferred tools of Image Guided Radiotherapy (IGRT) and Dose Guided Radiotherapy (DGRT) which have been used for Radiotherapy treatment verifications. As a result, the number of publications dealing with these two tools for radiation treatment verification has increased consi...

متن کامل

Three-dimensional gel dosimetry for dose volume histogram verification in compensator-based IMRT

Background: Some tissues in human body are radiobiologically different from water and these inhomogeneity must be considered in dose calculation in order to achieve an accurate dose delivery. Dose verification in complex radiation therapy techniques, such as intensity‐modulated radiation therapy (IMRT) calls for volumetric, tissue equivalent and energy independent dosimeter. The purpose of this...