AIMS Our aim was to clarify the location and structure of the outlet septum relative to the free-standing subpulmonary infundibulum in the setting of tetralogy of Fallot and to examine its relationship to the other components of the subpulmonary outflow tract, determining their potential influence on clinical outcome. METHODS AND RESULTS We studied prospectively 41 patients with tetralogy of Fallot (mean age 14 +/- 10.9 months) prior to surgical repair, and compared them with 15 patients undergoing closure of a ventricular septal defect associated with malalignment of the outlet septum but no subpulmonary infundibular stenosis (Eisenmenger ventricular septal defect), and 20 healthy controls. We also examined available autopsied hearts from cases with uncorrected tetralogy of Fallot (8) and Eisenmenger ventricular septal defect (13). Data were indexed for body surface area, and diameter of the tricuspid valve, respectively. The overall length of the subpulmonary infundibulum, including the extent of the muscular outlet septum, was significantly greater for patients with tetralogy of Fallot compared to normals (2.34 +/- 0.6 vs 1.46 +/- 0.34 cm/BSA0.5, P<0.001), whereas the difference between those with tetralogy of Fallot and an Eisenmenger ventricular septal defect was confined to the degree of narrowing of the subpulmonary outlet (0.43 +/- 0.22 vs 2.17 +/- 0.64 cm/BSA0.5, P<0.001). Within the tetralogy of Fallot group, there were linear relationships between deviation of the outlet septum (r= -0.61, P<0.005) and the diameter of the pulmonary valvar orifice (r=0.75, P<0.001), suggesting that growth of the pulmonary arteries may be related to this feature. When patients requiring a transannular patch as part of their surgical repair were compared with those not needing this procedure, differences were found in the diameter of the pulmonary valvar orifice and the pulmonary trunk, but not in the dimensions of the outlet septum. CONCLUSION The position of the outlet septum in relationship to the remainder of the muscular subpulmonary infundibulum represents a hallmark of tetralogy of Fallot, permitting its differentiation from Eisenmenger ventricular septal defects and normal hearts.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

بررسی عملکرد بطن‌ها با اکوکاردیوگرافی در نارسایی دریچه ریوی پس از جراحی تترالوژی فالوت

Background: Tetralogy of Fallot is the most common cyanotic congenital heart disease. The systolic and diastolic function in both ventricles is altered even after successful corrective surgery for this defect with a transannular patch. Pulmonary regurgitation, a common complication after this treatment, is usually well tolerated in childhood. The aim of this study was to assess the combined dia...

متن کامل

Echocardiographic findings of congenital absence of the pulmonary valve with tetralogy of Fallot.

The characteristic echocardiographic findings for congenital absence of the pulmonary valve with tetralogy of Fallot were described in three patients, whose diagnoses were confirmed by operation and/or autopsy. The abnormal linear echo, which was thought to be derived from the rudimentary pulmonary valve tissue, was recorded anteriorly to the dense echo from the subpulmonary muscle mass. The ec...

متن کامل

Aspergillus Fumigatus Endocarditis after Total Correction of Tetralogy of Fallot

There are few studies about post-cardiac surgery fungal infections especially by Aspergillus fumigatus. In this paper we report a case of Aspergillus fumigatus endocarditis after tetralogy of Fallot total correction (TFTC), and permanent pacemaker (PPM) implantation. A five-year-old female patient with current history of total correction of tetralogy of fallot was admitted in Rajaie Ca...

متن کامل

The anatomy of the atrioventricular conduction system in ventricular septal defect and tetralogy of fallot: correlations with the electrocardiogram and vectorcardiogram.

IN RECENT YEARS the morphological features of the major portions of the atrioventricular (A-V) conduction system of human hearts that were afflicted with various congenital anomalies have been described.1-6 These reports have contrasted the anatomy of the A-V conduction system in examples of ventricular septal defect (VSD) and tetralogy of Fallot with that configuration found in defects of the ...

متن کامل

Outcomes of Pulmonary Valve Replacement for Correction Pulmonary Insufficiency after Primary Repair of Tetralogy of Fallot (TOF)

Background Total correction of Tetralogy of Fallot (TOF) anomaly in early childhood has been practiced in many centers with good results, but in some of patients after few years sever Pulmonary valve insufficiency occurred. Materials and Methods At a cross- sectional study from January 2015 to January 2016, 10 patients who had history of primary repair of TOF with free pulmonary insufficiency (...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European heart journal

دوره 20 3  شماره 

صفحات  -

تاریخ انتشار 1999