Influence of the Arterial Input Function on Absolute and Relative Perfusion-Weighted Imaging Penumbral Flow Detection

نویسندگان

  • Walter Moeller - Hartmann
  • Jan Sobesky
چکیده

Background and Purpose—Perfusion-weighted imaging maps are used to identify critical hypoperfusion in acute stroke. However, quantification of perfusion may depend on the choice of the arterial input function (AIF). Using quantitative positron emission tomography we evaluated the influence of the AIF location on maps of absolute and relative perfusion-weighted imaging to detect penumbral flow (PF; 20 mL/100 g/min on positron emission tomographyCBF) in acute stroke. Methods—In 22 patients with acute stroke the AIF was placed at 7 sites (M1, M2, M3 ipsiand contralateral and internal carotid artery–M1 contralateral to the infarct). Comparative O-water positron emission tomography and AIF-dependent perfusionweighted imaging (cerebral blood flow, cerebral blood volume, mean transit time, and time to maximum) were performed. A receiver operating characteristic curve analysis described the threshold independent performance (area under the curve) of the perfusion-weighted maps for all 7 AIF locations and identified the best AIF-dependent absolute and relative thresholds to identify PF. These results were compared with AIF-independent time-to-peak maps. Results—Quantitative perfusion-weighted imaging maps of cerebral blood flow and time to maximum performed best. For PF detection, AIF placement did significantly influence absolute PF thresholds. However, AIF placement did not influence (1) the threshold independent performance; and (2) the relative PF thresholds. AIF placement in the proximal segment of the contralateral middle cerebral artery (cM1) was preferable for quantification. Conclusions—AIF-based maps of cerebral blood flow and time to maximum were most accurate to detect the PF threshold. The AIF placement significantly altered absolute PF thresholds and showed best agreement with positron emission tomography for the cM1 segment. The performance of relative PF thresholds, however, was not AIF location-dependent and might be along with AIF-independent time-to-peak maps, more suitable than absolute PF thresholds in acute stroke if detailed postprocessing is not feasible. (Stroke. 2012;43:378-385.)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of the arterial input function on absolute and relative perfusion-weighted imaging penumbral flow detection: a validation with ¹⁵O-water positron emission tomography.

BACKGROUND AND PURPOSE Perfusion-weighted imaging maps are used to identify critical hypoperfusion in acute stroke. However, quantification of perfusion may depend on the choice of the arterial input function (AIF). Using quantitative positron emission tomography we evaluated the influence of the AIF location on maps of absolute and relative perfusion-weighted imaging to detect penumbral flow (...

متن کامل

MRI perfusion maps in acute stroke validated with 15O-water positron emission tomography.

BACKGROUND AND PURPOSE Perfusion-weighted imaging maps are used to identify hypoperfusion in acute ischemic stroke. We evaluated maps of cerebral blood flow (CBF), cerebral blood volume, mean transit time, and time to peak (TTP) in acute stroke by comparison with positron emission tomography. METHODS Perfusion-weighted imaging and positron emission tomography were performed in 26 patients wit...

متن کامل

Arterial spin labeling versus bolus-tracking perfusion in hyperacute stroke.

BACKGROUND AND PURPOSE Arterial spin labeling (ASL) is a perfusion magnetic resonance imaging (MRI) technique that does not require contrast administration and thus may be more practical in hyperacute stroke than susceptibility-weighted bolus-tracking perfusion-weighted imaging (PWI). However, a threshold for ASL measurement of the ischemic penumbra needs to be determined. METHODS A total of ...

متن کامل

An Efficient Framework for Accurate Arterial Input Selection in DSC-MRI of Glioma Brain Tumors

Introduction: Automatic arterial input function (AIF) selection has an essential role in quantification of cerebral perfusion parameters. The purpose of this study is to develop an optimal automatic method for AIF determination in dynamic susceptibility contrast magnetic resonance imaging (DSC-MRI) of glioma brain tumors by using a new preprocessing method.Material and Methods: For this study, ...

متن کامل

Perfusion-weighted magnetic resonance imaging thresholds identifying core, irreversibly infarcted tissue.

BACKGROUND AND PURPOSE Identifying core, irreversibly infarcted tissue and salvageable penumbral tissue is crucial to informed, physiologically guided decision making regarding thrombolytic and other interventional therapies in acute ischemic stroke. Pretreatment perfusion MRI offers promise as a means to differentiate core from penumbral tissues. METHODS Diffusion-perfusion MRIs were perform...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012