The Effect of Lumbar Lordosis on Screw Loosening in Dynesys Dynamic Stabilization: Four-Year Follow-Up with Computed Tomography

نویسندگان

  • Chao-Hung Kuo
  • Peng-Yuan Chang
  • Tsung-Hsi Tu
  • Li-Yu Fay
  • Hsuan-Kan Chang
  • Jau-Ching Wu
  • Wen-Cheng Huang
  • Henrich Cheng
چکیده

INTRODUCTION This study aimed to evaluate the effects of Dynesys dynamic stabilization (DDS) on clinical and radiographic outcomes, including spinal pelvic alignment. METHOD Consecutive patients who underwent 1- or 2-level DDS for lumbar spondylosis, mild degenerative spondylolisthesis, or degenerative disc disease were included. Clinical outcomes were evaluated by Visual Analogue Scale for back and leg pain, Oswestry Disability Index, and the Japanese Orthopedic Association scores. Radiographic outcomes were assessed by radiographs and computed tomography. Pelvic incidence and lumbar lordosis (LL) were also compared. RESULTS In 206 patients with an average follow-up of 51.1 ± 20.8 months, there were 87 screws (8.2%) in 42 patients (20.4%) that were loose. All clinical outcomes improved at each time point after operation. Patients with loosened screws were 45 years older. Furthermore, there was a higher risk of screw loosening in DDS involving S1, and these patients were more likely to have loosened screws if the LL failed to increase after the operation. CONCLUSIONS The DDS screw loosening rate was overall 8.2% per screw and 20.4% per patient at more than 4 years of follow-up. Older patients, S1 involvement, and those patients who failed to gain LL postoperatively were at higher risk of screw loosening.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Screw loosening and Migration after Dynesys Implantation

Due to the problems associated with rigid fixation, the concept of dynamic stabilization was introduced. Dynesys is one of the pedicle screw-based dynamic stabilization systems. In spite of the dynamic nature of Dynesys, there are concerns about the rigidity of the Dynesys system. We present a case of vertebral body split fracture after Dynesys implantation in a 74-year-old woman. She had under...

متن کامل

[Pedicular dynamic stabilization system. Functional outcomes and implant-related complications for the treatment of degenerative lumbar disc disease with a minimum follow-up of 4 years].

INTRODUCTION The Dynesys(®) system is a non-fusion pedicular dynamic stabilization system. The aim of our study is to evaluate the clinical outcomes in patients with degenerative disc disease and/or stenosis, and to measure the prevalence of screw loosening and breakage after 4 years of follow up. MATERIAL AND METHODS All patients who underwent surgery with Dynesys(®) system in 2008 were revi...

متن کامل

Lumbar Single-Level Dynamic Stabilization with Semi-Rigid and Full Dynamic Systems: A Retrospective Clinical and Radiological Analysis of 71 Patients

BACKGROUND This study compares the clinical and radiological results of three most commonly used dynamic stabilization systems in the field of orthopedic surgery. METHODS A total of 71 patients underwent single-level posterior transpedicular dynamic stabilization between 2011 and 2014 due to lumbar degenerative disc disease. Three different dynamic systems used include: (1) the Dynesys system...

متن کامل

The Change of Sagittal Alignment of the Lumbar Spine after Dynesys Stabilization and Proposal of a Refinement

OBJECTIVE Dynesys® is one of the pedicle-based dynamic lumbar stabilization systems and good clinical outcome has been reported. However, the cylindrical spacer between the heads of the screws undergoes deformation during assembly of the system. The pre-strain probably change the angle of instrumented spine with time and oblique-shaped spacer may reduce the pre-strain. We analyzed patients with...

متن کامل

Intervertebral Disc Rehydration after Lumbar Dynamic Stabilization: Magnetic Resonance Image Evaluation with a Mean Followup of Four Years

Objective. To compare the clinical and radiographic outcomes in patients of different ages who underwent the Dynesys stabilization. Methods. This retrospective study included 72 patients (mean age 61.4 years) with one- or two-level lumbar spinal stenosis who underwent laminectomy and the Dynesys (Zimmer Spine, Minneapolis) dynamic stabilization system. Thirty-seven patients were younger than 65...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2015  شماره 

صفحات  -

تاریخ انتشار 2015