The effect of flow arrest on distal embolic events during arterial occlusion with detachable coils: a canine study.
نویسندگان
چکیده
PURPOSE To determine the effect of proximal flow arrest on the frequency and timing of distal embolic events during occlusion of the common femoral artery with detachable coils. METHODS Twenty-three complex fibered platinum coils were delivered into 10 common femoral arteries without proximal flow arrest. The arteries were continuously monitored for flow and embolic events by Doppler sonography during delivery and for at least 10 minutes after delivery of each coil. Thirty-four coils were delivered into 6 arteries after proximal flow arrest by inflation of a nondetachable balloon. After balloon deflation, each artery was monitored by Doppler sonography for 10 minutes. RESULTS In the 10 arteries occluded without flow arrest, 87 events (8.7 per artery) occurred, of which 47 were embolic and 40 were indeterminate. In the 6 arteries with flow arrest, the number of emboli detected was 3 (0.5 per artery). Embolic events occurred only if there was residual flow. In those arteries that were occluded when the flow-arrest balloon was deflated, no emboli were detected. CONCLUSIONS Proximal flow arrest virtually eliminates the risk of distal emboli during arterial occlusion with detachable fibered coils. The use of fibered coils, in conjunction with proximal flow arrest, allows for safe arterial occlusion when detachable balloons are not available or their use is not feasible.
منابع مشابه
Endovascular arterial occlusion accomplished using microcoils deployed with and without proximal flow arrest: results in 19 patients.
BACKGROUND AND PURPOSE Prior to their relatively recent FDA approval, detachable balloons for endovascular arterial occlusion had been available on only a limited basis. We evaluated the feasibility of permanent endovascular carotid and vertebral artery occlusion using microcoils deployed with and without proximal flow arrest in 19 patients. METHODS Permanent endovascular occlusion was perfor...
متن کاملRedefining Onyx HD 500 in the Flow Diversion Era
We report the largest US case series results using Onyx HD-500 (EV3), a new liquid embolic agent, in the successful treatment of 21 patients with wide-neck intracranial aneurysms (mean size 4.5 mm), which are at increased risk of incomplete occlusion or recanalization with standard endovascular intervention utilizing detachable platinum coils. All aneurysms were located in the anterior circulat...
متن کاملEndovascular embolization of unruptured vertebral dissection using Guglielmi electrolytically detachable coils: case report.
We present a patient with unruptured vertebral dissection whose angiograph showed further enlargement of the aneurysm, after a transient reduction in the size of the fusiform dilatation. Tolerance of parent artery occlusion was first confirmed by a balloon occlusion test. Both proximal and distal portions of the vertebral artery, including the dissected site, were occluded using Guglielmi elect...
متن کاملبررسی موارد ترومبو آمبولیزم شریانی اندامها در بیمارستان سینا 76-1370
"Arterial Thromboembolism" is the most common cause of "Acute Arterial Ischemia" of extremities. In this study, It is attempted to collect retrospectively some documentary information of all "acute arterial thromboembolic occlusions of the limbs".Materials and Methods: In descriptive retrograde study in Sina General hospital, all related records in this regard were collected from March 1991 to ...
متن کاملUse of onyx for transarterial balloon-assisted embolization of traumatic carotid cavernous fistulas: a report of 23 cases.
BACKGROUND AND PURPOSE TCCFs are a common complication following craniofacial trauma and are usually treated by coils or detachable balloons. The use of the liquid embolic agent Onyx as the sole agent for the treatment of TCCFs has been rarely reported. Herein, we summarized the preliminary experience and effectiveness of treating TCCFs with Onyx in 23 patients. MATERIALS AND METHODS From the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 17 4 شماره
صفحات -
تاریخ انتشار 1996